Murata Electronics North America DNT24 Manual Do Utilizador

Página de 83
www.Murata.com
Technical support +1.678.684.2000
Page 69 of 83
© 2015 by Murata Manufacturing Co. Ltd.
E-mail:
tech_sup@murata.com
DNT24 Integration Guide – 03/04/15
Figure 8.6.1.7
Figure 8.6.1.7 shows the I/O Parameters tab contents, corresponding to Bank 5. All GPIO ports are con-
figured as inputs. The 12-bit ADC input readings and DAC output settings are given in Big-Endian byte
order. Event flags are presented on the right side of the window.
Figure 8.6.1.8
Figure 8.6.1.8 shows the first I/O Settings tab contents, corresponding to Bank 6 GPIO configurations
other than alternate GPIO functions. This tab allows the direction of the GPIO ports to be set both for
active and sleep modes, and in the case of GPIO outputs, the initial power up states and sleep mode
states to be set. When GPIO ports 0 - 3 are configured as inputs, event interrupts can be set for them
with check boxes. The type of interrupt trigger is selected from the drop-down boxes to the right of the
check boxes. Periodic I/O reporting, reporting interval and enable/disable sleep I/O states and I/O binding
can also be configured under this tab.