Note the remote MAC address 0x0001 02 is entered in Little-Endian byte order, 0x02 0x01 0x00. The 
ADC reading is returned in a GetRemoteRegisterReply message: 
0xFB 0x0B 0x1A 0x00 0x02 0x01 0x00 0xC4 0x08 0x05 0x02 0xFF 0x02 
Substantial information is returned in the message. The last two byes of the message give the ADC 
reading in Little-Endian format, 0xFF 0x02. The ADC reading is thus 0x02FF. The RSSI value is the byte 
following the address, 0xC4 (-60 dBm). The TxStatus byte to the right of the GetRemoteRegisterReply 
Packet Type is 0x00, showing the packet was acknowledged on the RF channel. 
4.2.10 Protocol Mode Event Message Example 
In this example, the IO_ReportInterval set to 10 seconds and the periodic report timer bit in the 
IO_Report Trigger
 parameter is set on the remote with MAC address 0x1 23456. This causes event mes-
sages to be sent from this remote every 10 seconds. The IO_ReportInterval and the IO_Report Trigger 
parameters are loaded using SetRemoteRegister commands. The command to set the IO_ReportInterval 
to 10 seconds is: 
0xFB 0x0B 0x0B 0x56 0x34 0x12 0x1A 0x06 0x04 0xE8 0x03 0x00 0x00 
The IO_ReportInterval parameter starts in location 0x1A of bank 0x06. The report interval is set in 10 ms 
units,  so  a  10  second  report  interval  is  1000  units  or  0x000003E8  (Little-Endian  format  E8  03  00  00).  The 
IO_ReportInterval
 parameter is updated and SetRemoteRegisterReply is returned: 
0xFB 0x06 0x1 B 0x00 0x56 0x34 0x1 2 0xC4 
The command to set the periodic report timer bit in IO_Report Trigger to is: 
0xFB 0x08 0x0B 0x56 0x34 0x12 0x19 0x06 0x01 0x10 
The periodic report timer bit in IO_Report Trigger is located in bit position four (0001 0000b) or 0x1 0. The 
IO_Report Trigger 
parameter is updated and SetRemoteRegisterReply is returned: 
0xFB 0x06 0x1 B 0x00 0x56 0x34 0x1 2 0xC4 
The remote will start sending event messages on 10 second intervals as shown in the log records below: 
11:20:30.328: RX: FB 16 28 56 34  12 CB 00 05 0E 01 00 00 00 01 01 F9 01 DF 01 C9 01 10 00 
11:20:40.328: RX: FB 16 28 56 34  12 B6 00 05 0E 01 00 00 00 01 01 F8 01 DF 01 CC 01 10 00 
11:20:50.328: RX: FB 16 28 56 34  12 B3 00 05 0E 01 00 00 00 01 01 F8 01 E0 01 CC 01 10 00 
11:21:00.343: RX: FB 16 28 56 34  12 B1 00 05 0E 01 00 00 00 01 01 F9 01 DF 01 C9 01 10 00 
11:21:10.406: RX: FB 16 28 56 34  12 AE 00 05 0E 01 00 00 00 01 01 F9 01 DF 01 C8 01 10 00 
11:21:20.328: RX: FB 16 28 56 34  12 AD 00 05 0E 01 00 00 00 01 01 F9 01 E1 01 CF 01 10 00 
 
IO_Report Trigger
 generates RxEvent messages (Pkt Type 0x28). The message payload consists of the 
first 14 bytes in Bank 5, including the state of GPIO0 through GPIO5, the input voltages measured by 
ADC0  through  ADC2,  and  the  state  of  the  event  flags.  Note  the  ADC  readings  and the  event flags  are 
presented in Little-Endian order.