GPIO_SleepDir
 - when GPIO_SleepMode is enabled, this parameter functions as a secondary GPIO_Dir 
to set the direction of the GPIOs during a device’s sleep period. This enables the user to provide alternate 
configurations during sleep that will help minimize current consumption. Bits 0. .5 correspond to 
GPIO0..GPIO5. 
GPIO_SleepState
 - when GPIO_SleepMode is enabled, this parameter functions as a bitmask to set the 
output state of the GPIOs during a device’s sleep period. This enables the user to provide alternate 
configurations during sleep that will help minimize current consumption. Bits 0. .5 correspond to 
GPIO0. .GPIO5 respecively. 
PWM0_Init
 - this parameter sets the initial value for PWM0 at startup. 
PWM1_Init
 - this parameter sets the initial value for PWM1 at startup. 
ADC_SampleIntvl
 - this parameter sets the interval between the beginning of one ADC read cycle and the 
next ADC read cycle. The three ADC inputs are read on each ADC read cycle. An ADC_SampleIntvl 
count equals 10 ms. 
ADC0.  .2_ThresholdLo/Hi
  -  these  values  define  thresholds  to  trigger  an  I/O  report  based  on  ADC  meas-
urements.  If  I/O  reporting  is  enabled,  a  single  EVENT  report  containing  the  contents  of  the  I/O  bank  is 
generated when a threshold is crossed. Reporting is "edge-triggered" with respect to threshold bounda-
ries, not "level-triggered"; i.e., if the measurement remains there, additional reports are not triggered until 
the value crosses the threshold again. The thresholds are met whenever one of the following inequalities 
are satisfied: 
ADCx < ADCx_ThresholdLo 
ADCx > ADCx_ThresholdHi 
IO_Report Trigger
 - when a selected trigger source is enabled, a trigger event will cause the remote to 
send an EVENT message to its base containing the entire current values of the I/O Register Bank from 
GPIO0 up to and including the EventFlags, but not the PWM settings which are output-only. 
bit 7 
ADC2 high/low thresholds 
bit 6 
ADC1 high/low thresholds 
bit 5 
ADC0 high/low thresholds 
bit 4 
Periodic report timer 
bit 3 
GPIO3 edge 
bit 2 
GPIO2 edge 
bit 1 
GPIO1 edge 
bit 0 
GPIO0 edge 
I/O reporting is supported for remotes only, not the base. 
IO_ReportInterval
 - when periodic I/O reporting is enabled, this parameter sets the interval between 
reports. Units are 10 ms increments, and the default report interval is every 30 seconds.