Murata Electronics North America HN1510 Manual Do Utilizador

Página de 58
 
 
Configuring the Network 
M-2410-0010, Rev. - 
HopNet Family of Products 
31 
Protocol Commands 
These commands can be used to tune the transceiver for optimum transmission of 
data across the RF link.  For most applications, the default values are adequate. 
 
 
Command 
 
Description 
pe[?|0-4] 
Set Alternative Frequency Band 
 
0 = FCC/ETSI operation.  (~2401 – 2471MHz) (default) 
 
1 = France (~2448 – 2473MHz) 
 
2 = Spain (~2448 – 2473MHz) 
 
3 = Japan (~2473 – 2495MHz) 
 
4 = Canada (~2452 – 2478MHz) 
 
ph[?|00-fe] 
(base only) 
 
Set Hop Duration 
 
90H = default (=10ms) 
 
pk[?|00-d0] 
   
 
Set Minimum Data Length 
 
01 = default 
 
pl? 
   
 
Get Maximum Data Length 
 
D4 = default (=212 bytes) 
pn[?|01-3e] 
(base only) 
Set Maximum Number of Remotes 
 
3e = default (=62 remotes) 
 
pr[?|00-ff] 
                                   
 
Set Packet Attempts Limit 
 
10H = default 
 
FFH = Infinite retry 
(RF flow control point-to-point 
only)
 
 
pt[?|00-ff] 
 
 
Set Data Transmit Delay 
 
00H = default    
pv[?|0|1] 
 
(base only) 
Set Slot Assignment Mode 
 
0 = default (dynamic slot assignment) 
 
1 = static slot assignment 
pw[?|00-34] 
(base only) 
Set Base Slot Size 
 
08H = default (=32 bytes) 
px[?|0|1] 
Set ARQ mode.   
 
0  = ARQ enabled (default) 
 
1  = ARQ disabled (redundant transmission) 
Note: Incorrect setting of these parameters may result in reduced throughput or loss of data 
packets.