The Status of CONNECTED indicates the radio is communicating with ZBDemo and has
nothing to do with whether or not the radio is part of a ZigBee network. Even when the radio is
configured as a Router or End Device, the Status will indicate CONNECTED.
Each radio will have a different Network Address. As radios are discovered, they will be made
available in the Network Address drop down menus. This allows you to selectively display any
individual radio’s parameters using the Network Address drop down menu. For situations in
which more than 5 radios are being used, this feature allows you to view and/or reorganize how
the parameters are displayed.
There are Poll Radio checkboxes at the bottom of each Radio column that allow the radio to be
periodically polled for information when the Start button is pressed under the Refresh Delay
field. A setting of 0 seconds in the Refresh Delay field will continuously poll the Radios that have
Poll Radio checked. Longer Refresh Delay settings can be set using the up and down arrows to
the right of the Refresh Delay field, or the number can be highlighted and a value entered. Once
the Start button is pressed, it changes to a Stop button. Clicking on the Stop button will end the
polling process.
nothing to do with whether or not the radio is part of a ZigBee network. Even when the radio is
configured as a Router or End Device, the Status will indicate CONNECTED.
Each radio will have a different Network Address. As radios are discovered, they will be made
available in the Network Address drop down menus. This allows you to selectively display any
individual radio’s parameters using the Network Address drop down menu. For situations in
which more than 5 radios are being used, this feature allows you to view and/or reorganize how
the parameters are displayed.
There are Poll Radio checkboxes at the bottom of each Radio column that allow the radio to be
periodically polled for information when the Start button is pressed under the Refresh Delay
field. A setting of 0 seconds in the Refresh Delay field will continuously poll the Radios that have
Poll Radio checked. Longer Refresh Delay settings can be set using the up and down arrows to
the right of the Refresh Delay field, or the number can be highlighted and a value entered. Once
the Start button is pressed, it changes to a Stop button. Clicking on the Stop button will end the
polling process.
5.1 Discover
Radios
Once the ZBDemo has connected to the board, if the Link LED is illuminated, ZBDemo can
discover the nodes that are part of the network. The Discover Radio button causes up to four
radios that are part of the same ZigBee network as the Coordinator to be displayed at any one
time and will read the status of the various components of each radio. Using the Network
Address drop down menu, additional radios can be selected and their parameters displayed
and/or changed. The status of each Radio will be LINKED. The MAC Address window will
display the actual MAC address of each radio and the Switch, LED, Thermistor and
Potentiometer windows will display the status of each component on the development board.
The values that were present when the Discover Radios button was clicked will be displayed but
the values will not be Refreshed until the Start button has been clicked. The Discover command
can be issued from a Coordinator, Router, or End Device.
discover the nodes that are part of the network. The Discover Radio button causes up to four
radios that are part of the same ZigBee network as the Coordinator to be displayed at any one
time and will read the status of the various components of each radio. Using the Network
Address drop down menu, additional radios can be selected and their parameters displayed
and/or changed. The status of each Radio will be LINKED. The MAC Address window will
display the actual MAC address of each radio and the Switch, LED, Thermistor and
Potentiometer windows will display the status of each component on the development board.
The values that were present when the Discover Radios button was clicked will be displayed but
the values will not be Refreshed until the Start button has been clicked. The Discover command
can be issued from a Coordinator, Router, or End Device.
5.2 Refresh
Delay
The Refresh Delay sets the frequency with which information from all radios, local and remote,
is updated. The frequency can be adjusted in one second increments. A value of zero
corresponds to a continuous updating. Since an updating of each radio requires a number of
individual read and write commands, it may take a second to update each radio even if the
Refresh Delay is set to zero. This time is a function of Windows and ZBDemo and not the
ZigBee module.
Once the Refresh Delay has been chosen, click on the Start button to begin the updating. The
status bar on the bottom left corner of the ZBDemo screen will indicate the progress being made
by the program. When ZBDemo is updating the radio data, the Start button will change to a Stop
button. When ZBDemo is idle, the Stop button will return to the Start button. If the Poll Radio
box is unchecked for a radio, that radio will not have its information updated.
is updated. The frequency can be adjusted in one second increments. A value of zero
corresponds to a continuous updating. Since an updating of each radio requires a number of
individual read and write commands, it may take a second to update each radio even if the
Refresh Delay is set to zero. This time is a function of Windows and ZBDemo and not the
ZigBee module.
Once the Refresh Delay has been chosen, click on the Start button to begin the updating. The
status bar on the bottom left corner of the ZBDemo screen will indicate the progress being made
by the program. When ZBDemo is updating the radio data, the Start button will change to a Stop
button. When ZBDemo is idle, the Stop button will return to the Start button. If the Poll Radio
box is unchecked for a radio, that radio will not have its information updated.
5.3 Switches
The Switch0 and Switch1 windows display the state of the two momentary push button switches
on the development board. When the switches are open, the window will display
on the development board. When the switches are open, the window will display
0x01