Murata Electronics North America Z2430A Manual Do Utilizador

Página de 59
ZMN2405/ZMN2405HP Dev Kit 
© 2007-2008 RFM Inc. 
30 
M-2405-0000 Rev. C- 
 
5.9.1 Config 
Tab 
 
 
The Serial Baudrate sets the communication rate for the UART port of the module. Changes 
take effect immediately upon clicking Apply.  
 
The Model Number field shows whether the device is a Coordinator, Router or End Device. 
 
Friendly Name
 is a 16-byte field that allows user-defined names to be assigned to modules for 
easier identification in the field. It allows the user to assign applicable names to each radio in 
the system, i.e. Main Office for the Coordinator and Pump Well 1 for the Router out on the site 
and so on.  
 
Sleep Mode
 This is used on End Devices Only. Checking this box will configure the module as 
a battery-powered sleeping node. The default sleep mode is Timer Sleep. If Interrupt Sleep 
mode is desired, it can be selected under the Confg Enable Options tab. This setting should be 
configured before the device joins the network. If it is changed after the device has joined the 
network, all devices in the network must be power cycled or reset, starting with the coordinator, 
to insure the network functions properly. 
 
Device Mode
 This is currently Read Only.  On read back it will be 
0x00
 for a Coordinator, 
0x01
 
for a Router, and 
0x02
 for an End Device. 
 
Transparent Mode
  A check is this box implements Transparent Mode and allows data without 
the CSM packetization to be transmitted.  Any data appearing on the serial input will be 
transmitted to the coordinator. Data received by the device will also be output by the module 
without the CSM packetization. Once you enter Transparent Mode, ZBDemo will no longer work 
since it is expecting data to be in CSM packets. See Section 8.2 for details on protocol mode. 
Transparent Mode is only for a Router or End Device.