3. Cut back the negative lead 3 cm (1.2 in.) to offset each power cable so the positive lead is 
longer than the negative lead.
4. Remove 2 cm (3/4 in.) of the insulation from both conductors on each power cable, and from 
both leads of the luminaire.
5. Tightly twist the 3 wires together to form a single conductor, and trim the single conductor back 
to 15 mm (3/8 in.) (i.e., 2 negative conductors from power cables and black lead from 
luminaire; 2 positive conductors from power cables and red lead from luminaire).
6. Insert the single conductor fully into the open-ended connector and verify through the 
translucent connector before crimping.
7. Make the crimp. If the crimp tool you are using does not cover the full length of the internal 
crimp ring make a second crimp.
8. Repeat this procedure for the power cables’ positive conductors and the red lead from the 
luminaire.
9. Temporarily apply power to test the connection.
Figure 22: Stripping the leads
Figure 23: Forming a single conductor
Figure 24: Preparing the splice
Figure 25: Crimping the splice
2 cm (3/4 in.) 1 : 1 scale
15 mm (0.6 in.) 1 : 1 scale
insulation visible
copper wires visible
no visible wires
first crimp