COOPER INDUSTRIES INC FH1848D Manual Do Utilizador

Página de 31
26
Parameter
Display
Type
Min.
Max.
Increm.
Default
Cannot Go Below
Cannot Go Above
PWM Drive Frequency
for R1300 Proportional
Outputs 1+/- through
4+/-
Solid 1+ Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for R1300 Proportional
Outputs 5+/- and 6+/-
Solid 1-
Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for S20 Proportional
Outputs O1 through O8
Solid 2+ Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for S20 Proportional
Outputs O9 through O16
Solid 2-
Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
E
N/A
N/A
Boom Load Moment
Limit
Solid 3+ Mult.-
Choice
A = 2500000 inch-lbs
A
N/A
N/A
Boom Derating Factor,
Ground Operation (%)
Solid 3-
Variable
Value
20
150
2
84
N/A
N/A