L3 Technologies AFIRS228S Manual Do Utilizador

Página de 106
 
AFIRS 228S Iridium Global Communications System Installation Manual
 
16 July 2014 
L-3 Aviation Recorders Proprietary 
Page 26 
165E5733-00 Rev. 03 
3.5.7.1 Configurable Inputs 
Each configurable discrete input is individually software-configurable for the following: 
• 
Signal Level: Open-Ground (Negative-Seeking) or Open-28V (Positive-Seeking) 
• 
Logic Assignment: Active Low or Active High 
• 
Function: Selected from list 
Refer to Section 6.9 for additional information on use of configurable inputs. 
3.5.8  Discrete Outputs 
Each discrete output transitions between an “Open Circuit” (high-impedance-to-ground) and a “Closed 
Circuit” (low-impedance-to-ground) state to indicate a change in output logic. 
Quantity 
8 Configurable 
“Open Circuit” Impedance 
>100 kΩ 
“Open Circuit” Voltage (Max) 
36 VDC 
“Closed Circuit” Current Limit (Min) 
500 mA 
Voltage Across “Closed Circuit” 
<1.25 V 
3.5.8.1 Configurable Outputs 
The discrete outputs use “Open-Closed” signal levels, where the output is either high-impedance to 
ground (Open) or low-impedance to ground (Closed). Each configurable discrete output is individually 
software-configurable for the following: 
• 
Logic Assignment: Active Low (Closed) or Active High (Open) 
• 
Function: Selected from list. 
Refer to Section 6.10 for additional information on use of configurable outputs.