L3 Technologies AIS Manual Do Utilizador

Página de 70
Marine Systems
Aviation Recorders
Rev. 02 Page 3--14
July 29/03
Automatic Identification System
NOTE:
Each shielded twisted pair of wires is shielded as well by
metallic shielding and a drain wire connected to this shield-
ing is to be connected in accordance with Table 3--2.
Table 3--2. IEC Cable and Junction Box Pinouts
Cable
STP
Wire Color
IEC Pin
TB Pin
1
White / Blue
1
1
Blue / White
11
2
Drain
22
3
2
White / Orange
2
4
Cable 1
Orange / White
12
5
Drain
25
6
3
White / Green
3
7
Green / White
13
8
Drain
23
9
Shield Drain
NC
10
4
White / Brown
4
11
Brown / White
14
12
Drain
24
13
5
White / Gray
5
14
Cable 2
Gray / White
15
15
Drain
26
16
6
Red / Blue
6
17
Blue / Red
16
18
Drain
27
19
Shield Drain
NC
20
7
Red / Orange
8
21
Orange / Red
19
22
Drain
29
23
8
Red / Green
9
24
Cable 3
Green / Red
20
25
Drain
30
26
9
Red / Brown
10
27
Brown / Red
21
28
Drain
31
29
Shield Drain