Motorola Mobility LLC P56JE1 Manual Do Utilizador

Página de 36
C24 Hardware Interface Manual 
Version 0.3 
Parameter 
Conditions 
Min 
Typ 
Max 
Units 
Temperature 
Operating range 
-30 
 
85 
°C 
Range 
Tolerance 
 
 
 
Resolution 
 
 
 
°C 
 
 
2.9.3 
General Purpose A/D 
 
The module provides 3 additional general purpose A/D (GPAD) signals for customer application use. 
Each A/D signal can monitor a separate external voltage and report its measured level independently to 
the application, through the AT command interface. The A/D Signals are available at the connector in the 
following pins: 37, 43 and 47. 
 
The GPAD signals can sense a DC voltage level of 0 – 2.3 V, which is converted internally to a 10-bit 
digital value.  
 
 
 
TABLE 22 – GPAD Specifications 
Parameter 
Conditions 
Min 
Typ 
Max 
Units 
Input Voltage 
 
 
2.9 
Sampling 
 
0.05 
 
2.5 
Range 
Resolution 
 
 
 
10 
mV 
 
 
 
Motorola General Business Use 
Page 31 of 36 
Applicant: Motorola, INC
FCC ID: IHDP56JE1