Indyme Solutions Inc 303MICA Manual Do Utilizador
Technical Document
CB440/511 Programming and Install Instructions
1
P/N: 430223-00 Rev R
CB440/511 Programming and Installation Instructions
Determine individual call box addresses prior to starting the
installations. Un-programmed call boxes default to address 001
(Alarm Code-1). Triggering a call box at this address may trigger an
advisory message or no action at all.
installations. Un-programmed call boxes default to address 001
(Alarm Code-1). Triggering a call box at this address may trigger an
advisory message or no action at all.
Programming the CB440/CB511 Call Box Address
1. Set the internal programming jumpers for
Address Programming:
Address
Programming
Mode
Programming
Disable
Programming
CB440
JP1
OFF ON ON
CB511
JP2
OFF ON OFF
HELP
= “PRESS HERE”
RESET
= “small white circle”
2. Press and hold RESET until the LED flashes one time. (approximately 8-seconds). The unit is now
in address programming mode.
3. The
HELP and RESET buttons are used to program the 3-digit address. Leading zeros are
required. HELP = digits 1-9, RESET = digit 0 and SAVE.
4. For example, program Alarm-802 as follows:
• Press
HELP 8-times, RESET once to save. (8)
• Press
RESET once to represent the zero.
(0)
• Press
HELP 2-times, RESET once to save. (2)
Note: The LED will flash with each press of the HELP button. When the RESET button is pressed
to save the 3
to save the 3
rd
digit, the LED will flash to indicate the address that was entered. The LED will
indicate digit zero by a long flash. (approximately 1-sec.)
5. Program each call box according to the mounting location.
6. Set the jumpers to “Disable” to prevent accidental changes and install the call box module.
JP1
JP2
CB440/511 PCA
NOTE: In both Address and Mode programming, if no buttons are pressed for 30 seconds, the
unit will timeout and return to normal operating mode. The LED will flash five times upon
exit of either mode and any changes made will be lost.