Indyme Solutions Inc 303MICA Manual Do Utilizador

Página de 2
 
Technical Document 
CB440/511 Programming and Install Instructions 
P/N: 430223-00 Rev R 
CB440/511 Programming and Installation Instructions 
Determine individual call box addresses prior to starting the 
installations. Un-programmed call boxes default to address 001 
(Alarm Code-1). Triggering a call box at this address may trigger an 
advisory message or no action at all.
 
 
Programming the CB440/CB511 Call Box Address 
1.  Set the internal programming jumpers for                           
      Address Programming: 
 
 
 
Address 
Programming 
Mode 
Programming 
Disable 
Programming 
CB440 
JP1 
OFF ON  ON 
CB511
JP2 
OFF ON  OFF 
HELP
 = “PRESS HERE”     
RESET
 = “small white circle” 
2.  Press and hold RESET until the LED flashes one time. (approximately 8-seconds). The unit is now 
in address programming mode. 
3. The 
HELP and RESET buttons are used to program the 3-digit address. Leading zeros are 
required. HELP = digits 1-9, RESET = digit 0 and SAVE. 
4.  For example, program Alarm-802 as follows: 
• Press 
HELP 8-times, RESET once to save.  (8) 
• Press 
RESET once to represent the zero. 
(0) 
• Press 
HELP 2-times, RESET once to save. (2) 
Note: The LED will flash with each press of the HELP button. When the RESET button is pressed 
to save the 3
rd
 digit, the LED will flash to indicate the address that was entered. The LED will 
indicate digit zero by a long flash. (approximately 1-sec.)  
5.  Program each call box according to the mounting location. 
6.  Set the jumpers to “Disable” to prevent accidental changes and install the call box module.  
 
JP1
JP2
CB440/511 PCA 
 
 
NOTE:  In both Address and Mode programming, if no buttons are pressed for 30 seconds, the 
unit will timeout and return to normal operating mode. The LED will flash five times upon 
exit of either mode and any changes made will be lost.