Indyme Solutions Inc CB526 Manual Do Utilizador

Página de 2
 
 
Technical Document 
430668-00 
Rev. E 
Indyme Solutions, Inc. 8295 Aero Place  San Diego, CA 92123 USA                  
                                        +1.858.268.0717  +1.800.829.6141Page 1 of 2 
CB526 Pocket Director Call Box
 
 
             
Programming the CB526:  
If at any point during the programming sequence 30 seconds expire without a button being pressed, the address 
programming mode will be exited and the previously programmed address will continue to be used.  The 
assurance LED will flash 5 times to indicate that mode programming has been exited. 
 
1.  Press and hold button 2 for 5 seconds.  The assurance LED will flash once. 
2.  Press and hold button 1 for 5 seconds.  The assurance LED will flash twice. 
3.  Press and hold button 2 for 5 seconds.  The assurance LED will flash three times.   
4.  Press button 1 once. 
5.  Press button 2 once, the assurance LED will flash once.   
You are now in Address Programming Mode. 
6.  To program the hundreds value, press button one 1-9 times.   
7.  Press button two, one time to save the hundreds value. 
8.  To program the tens value, press button one 1-9 times.   
9.  Press button two, one time to save the tens value. 
10. To program the ones value, press button one 1-9 times.   
11. Press button two, one time to save the ones value.   
The assurance LED will now flash back the address that was programmed. 
NOTE: 
To program the number zero (“0”) do not press button 1, instead, press 2.  
 
During the flash back sequence, the LED indicates a zero by staying on longer. 
 
 
 
 
The  CB526  is  a  mini  director  call  box  designed  for  pocket  or 
clip-on use. The 4-membrane switch assembly is 
designed without a reset button and is intended to be carried 
by store employees desiring to trigger messages from various 
locations within the store. 
 
The CB526 call box has a single assurance LED, it will flash for 
¼-sec when a button is pressed.