Selex Sistemi Integrati Inc. VOR2 Manual Do Utilizador

Página de 254
Model 1150A DVOR 
 
9-16 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
9.7.6 DVOR Station Power-Up
Refer  to 
  of  this  manual  for  detailed  instruction  on  DVOR  operation.    The  DVOR  is  microprocessor 
controlled, transmitter one will come up in the on-line mode as the normal mode of operation. 
 
a. 
Turn on the PMDT. Refer to 
 for operating instructions. 
b. 
Set TX1 AC and TX 2 AC circuit breakers to the ON position. 
c. 
Set TX 1 Battery and TX 2 Battery circuit breakers to the ON position. 
d. 
Set TX 1 DC Buss and TX 2 DC Buss circuit breakers to the ON position. 
 
9.7.7 Log-On Procedure
a. 
Refer to 
for DVOR system log on procedures. 
b. 
Place system in bypass using the PMDT mouse to point and click the BYPASS button on the left side of 
the display command and shutdown transmitter by pointing and clicking the OFF button on the screen. 
 
9.7.8 Setting Date and Time
a. 
Point and click the RMS TAB pull down menu. 
b. 
Select set time and date and push the enter key. 
c. 
The RMS time will be updated to the current time on the PMDT laptop. 
 
9.7.9 Setting Station's Descriptor
Refer to 
 for this procedure. The station descriptor is an alpha or numeric descriptor that allows 
you  to  readily  identify  a  DVOR  system.  This  is  very  useful  when  there  is  more  than  one  system  that  you  are 
monitoring. This information is not broadcast by the DVOR. 
 
9.7.10 Password Change
Refer to 
 for this procedure. 
 
9.7.11 Setting System Configuration
Refer to 
 for this procedure. 
 
9.7.12 Transmitter Tuning Procedures
9.7.12.1 Checking Output Frequency of Frequency Synthesizer
a. 
Perform procedure of 
 to align the Frequency synthesizers
.
9.7.12.2 Amplitude Adjustment
a. 
Turn off transmitter by using the mouse to point and click on the Transmitter 1 OFF button.   
b. 
Connect in-line wattmeter thru body in the carrier feed cable to the antenna. Install a 250 watt element into 
the wattmeter to measure forward power. 
c. 
Turn on transmitter 1 by using the mouse to point and click on the Transmitter 1 ON button.   
d. 
Insure that transmitter 1 is on the antenna. 
e. 
Place transmitter in the BYPASS mode of operation. 
f. 
Select Transmitters>>Configuration>>Nominal.  Enter the desired Output Power from 0 to 100 Watts then 
F7.  Select Transmitters>>Configuration>>Offsets and Scale Factors.  Adjust the Output Power Scale for 
Transmitter 1 to obtain the desired output power. 
 
NOTE 
If the VOR is to be operated as an enroute facility, use the 250 watt element and set the station for 
100 watts.  If the facility is to be used as a terminal facility, use the 100 watt element and set the 
station  for  50  watts.    Other  power  settings  between  50  and  100  watts  should  be  at  customer's 
request.  Use the wattmeter element that provides the best display.