HID Global Corporation 5553 Manual Do Utilizador
HF Multi ISO RFID Reader User Manual, Firmware V1.4
1508-USM-00-0-04
2.3.6.2
ISO-A tag manual activation sequence - Example
For single tag applications
Command
Answer
t01 E3 26
02 04 00 (send REQA)
05 81635640F4 (81635640F4 denotes SN of tag)
t02 03 93 20
For multi-tag applications
Command
Answer
m<CR>
List of accessible tags.
To select a specific tag (after sending REQA)
Command
Answer
t07 0F 93 70 81635640F4
01 88 (Select card 81635640F4)
After selecting a tag, additional parameter selection is done by the RATS sequence.
Command
Answer
t02 0F E0 20 (send RATS)
ATS bytes (refer to ISO 14443-4 section 5.2)
2.3.6.3
ISO-B tag manual activation sequence - Example
For single tag applications
Command
Answer
t03 0C 05 00 08
(REQB, 1 time slot)
(REQB, 1 time slot)
0C 50 34030F07 63223344000002
For multi-tag applications: As above, use Multi-Tag List.
To select a specific tag (after sending REQB)
Command
Answer
t09 0C 1D 34030F07 00 02 01 00
01 00
2.3.6.4
Using SLE66CLX320P - Example
Since the SLE66CLX320P supports chip functionality, the transfer command must be used. To
set up a communication with the tag, the tag must be appropriately initialized. First the card must
be selected and then it is initialized sending the ATS. Afterwards the application specific
commands can be issued.
set up a communication with the tag, the tag must be appropriately initialized. First the card must
be selected and then it is initialized sending the ATS. Afterwards the application specific
commands can be issued.
The following table describes the initialization of a SLE66CLX320P:
Command
Answer
s
05 23 74 87 15 1B 04
Select card with UID 05237487151B04
Select card with UID 05237487151B04
t02 0F E0 50
0F 0F 77 11 E4 02 00 64 05 7D 02 03 31 80 90 00
Send ATS.
Send ATS.
August 2010
Page 95 of 144
© 2005-2010 HID Global Corporation. All rights reserved.