Hughes Network Systems HNS9350 Manual Do Utilizador

Página de 48
 
Hughes 9350 BGAN Terminal User Guide 
11
 
2.  PS Attach Status:  This field indicates whether you are PS (Packet Switch) attached with 
the Network.   You will still need to setup a PDP context in order to send PS data.    
3.  CS Attached: This indicates whether you are CS (Circuit Switch) attached with the 
Network.  Once you are CS Attached and Registered with the network, you are able to 
make CS calls. 
4.  GPS Position: This field displays the current GPS position status.  If you have received a 
GPS fix and the Network GPS policy has been received and it allows the GPS position to 
be shown to the user, it will display the Latitude, Longitude, Fix Quality, and the Last time 
the GPS position was updated.  Time displayed is GMT time. 
5.  Emergency Call Numbers: This field displays the Emergency call numbers that can be 
used with the UT. 
6.  Software Version:  This displays the current version of software that is running on the UT. 
7.  Satellite Modem IMEI:  This displays the IMEI number of the UT. 
8.  Satellite Modem IMSI:  This displays the IMSI number of the USIM card in the UT. If is the 
IMSI is not displayed, it indicates that there is a problem reading the SIM card, e.g. 
because there is no SIM, it is installed incorrectly or PIN must be entered. 
9.  USIM PIN Status: This field indicates whether the USIM is ready or the PIN has to be 
entered. If the PIN needs to be entered, go to the SETUP page. 
10.  USIM APN Name: This displays the default APN that has been provisioned on the USIM 
card.  Note that some USIM cards may have multiple APN’s provisioned on them. 
11.  MS-ISDN 1 thru 4:  Every USIM card has four (4) separate MS-ISDN numbers if the USIM has 
been provisioned for these services.  MS_ISDN 1 is for 4K Speech, MS-ISDN 2 is for 3.1KHz 
Audio (fax, etc.), MS-ISDN 3 is for UDI data and MS-ISDN 4 is for RDI data. 
12.  Extract System Log: Clicking this button allows the User to automatically extract a UT 
system log and save the file to a location on the TE for debugging purposes.  This file can 
be e-mailed to Hughes directly for fault analysis if the User experiences any problems. 
13.  Restore factory Defaults:  Clicking this button will restore the UT back to factory defaults 
and delete any of the User parameters that have been set-up in the UT.  Hughes highly 
recommends that the User exhaust all possible debug procedures before using this 
feature.