Itron Inc. CCU100A Manual Do Utilizador
Tower Installation
TDC-0971-011 CCU 100 and Repeater 100 Installation Guide
41
Proprietary and Confidential
TCU Components
1
RF Filter
2
Battery
3
Surge protection devices (SPDs), receptacle, terminal blocks
4
Collector mounting plate
5
Roxtec™ block
6
Wiring diagram
7
Document holder
8
Air filters There are two air filters, one shown at (8) and another behind the fan (9).
9
Fan
To assemble the Tower CCU 100
Important This unit must be installed in accordance with the National Electrical
Code and with all local codes. Provide power to the cabinet using electrical
conduit. Itron recommends using a knockout punch and die (such as a Greenlee®
Slug-Buster®) to punch the appropriate sized hole in the bottom of the cabinet.
Code and with all local codes. Provide power to the cabinet using electrical
conduit. Itron recommends using a knockout punch and die (such as a Greenlee®
Slug-Buster®) to punch the appropriate sized hole in the bottom of the cabinet.