Mounting Hardware 
Depending on your installation location and configuration, the following mounting 
hardware must be supplied by the installer to properly attach the CCU/Repeater to the 
mounting surface.   
 
Caution  Since each installation is unique, you must ensure that the mounting 
hardware you supply can securely support the CCU/Repeater. The CCU/Repeater 
(minus attachment hardware) weighs 7 pounds. Itron recommends consulting with a 
qualified engineer to verify load requirements and safety issues. Also, be sure to 
check and comply with local codes when installing the CCU/Repeater.  
  
 
Profile 
Mounting surface 
Suggested hardware/sizing 
Utility pole 
Wood or steel pole  
High-strength stainless steel straps 
Light pole 
Steel light pole 
High-strength stainless steel straps 
Outdoor wall or pole with 
remote antenna 
Concrete, wood, or steel wall  
1/4 inch-20 lag screws or 1/4 inch-20 molly bolts 
Wood or steel pole 
High-strength stainless steel straps 
Indoor wall or pole with 
remote antenna 
 
Concrete, wood, sheetrock, or 
steel wall  
1/4 inch-20 lag screws or 1/4 inch-20 molly bolts 
Wood or steel pole 
High-strength stainless steel straps 
Pipe 
2.5 inch to 3.5 inch galvanized 
steel pipe 
Two pipe mount brackets for pipes up to 3.5 inches in 
diameter, supplied by Itron (part number FAB-0192-
001, two brackets are required for each 