Battery Storage and Charging 
 
 CCU 100 and Repeater 100 Installation Guide 
 
45 
 
Proprietary and Confidential 
 
State of Charge 
The state of charge (SOC) of the battery can be approximated by using the curve shown in 
the chart below. This curve is accurate to within 20% of the true SOC of the cell under 
consideration, if it has not been charged or discharged within the past 24 hours. The curve is 
accurate to within 5% if the cell has not seen any activity, charge or discharge, for the past 
five days. 
 
 
Charge the Battery 
You can charge spare CCU/Repeater batteries individually or in groups to save time.  
When charging batteries, there are several items you need:  
•  Power Sonic PSC-124000A-C charger 
•  Molex 39-01-4046 connector 
•  CCU/Repeater batteries 
The recommended method for charging the batteries is to utilize the Power Sonic PSC-
124000A-C charger. The Power Sonic charger needs to be modified so that it can be 
plugged directly into the battery. This is done by retrofitting the output of the charger to a 
Molex 39-01-4046 connector with the red wire going to pin one and the black wire going to 
pin two of the connector. Follow the instructions that come with the charger for correct 
operation. 
After charging, the battery should be removed from the charger for at least 24 hours. After 
this time the open circuit voltage should be measured to verify that it is at or above 6.4 
volts.  
 
Note  Batteries in storage need to be charged routinely for maximum shelf life. For 
more information, see 