Itron Inc. FNCCU4 Manual Do Utilizador

Página de 58
DRAFT
36
CCU4 Collector Field Installation and Service Guide
TDC-0359-000b 04/02
Environmental
Environmental
Power
AC Power
The CCU4 collector operates on a 120 VAC, 60 Hz supply only. The collector is double insulated
and does not require an earth ground connection.
The collector input AC connector is a five position circular 3A/300V connector. Pins 2, 3 and 4
are voided for high voltage line to line clearance. The five position circular connector is mounted
on the collector housing, providing a watertight connection point for external power sources.
Table 6:
Environmental Specifications
Specification
Value
Operating Temperature, component
-40°C to +85°C (-40°F to + 185°F)
Operating Temperature, battery
-20°C to +60°C (-4°F to +140°F)
Storage Temperature
-40°C to +85°C (-40°F to + 185°F)
Humidity
Per MIL Standard 810
Solar Heat Load Exposure
?
UV Stability
?
Mechanical Vibration
Per ANSI Standard C12 Paragraph 4.7.3.20.
5-350 Hz (with a sweep time of one octave
per minute at .5 g)
Drop Requirements
?
Salt Spray
Per ANSI Standard C12 Paragraph 4.7.3.23.
Pass 25-hour salt spray test in accordance
with ASTM B117-85
Rain Tightness
Per ANSI Standard C12 Paragraph 4.7.3.24
Weather Simulation
Test Per ANSI Standard C12 Paragraph
4.7.3.22
Table 7:
Power Specifications
Specification
Value
Voltage
96-144 VAC
Frequency
60 Hz