Paragon-III  Technical Manual
17
Table 3 - Checklist A (After installation)
CHECKLIST A
(
Paragon-III
)
Recommended Check out after Installation
Step
ACTION
EXPECTED RESULTS
at 25
°°°°
C
MEASURE WITH
IF NOT?
1
Normal Power-up
Sequence
BDLC-III beeps once, all LEDs come ON for about four seconds, the green
LEDs then flash in a “ripple” pattern for close to two seconds. All LEDs go OFF
except the CK that should flash 6 to 8 times per second.
2
Connect and save unit
config
Press CDip Get button
as per CDip Help content
3
Transmitter Output
Power
Press TXON (Unmod)
UHF: 20 - 100 watts
800 MHz: 20 - 70 watts
+10%, -10%
Service monitor set
to read power
or
150W in-line watt-
meter installed as
close as possible to
the unit antenna
connector.
1
Check for bad connec-
tions, damaged coax cable,
etc.
4
Transmitter Reflected
Power
Press TXON (Unmod)
< 5% of forward power or
as specified by System
Engineering.
10W in-line watt-
meter
Check for bad connections,
damaged coax cable, etc.
5
RF Link test
Use the mobile address
function and “Send” but-
ton to dynamically test
the link
Look for
“Delivery confirmed” on
the Status bar
WinRIS Help
content.
Mobile is out of  range
Refer to factory technical
support.
                                           
1
 (unless unit has been set a lower value). Note that readings less than 100 watts for UHF or 70 watts for 800 MHz models, may be due
to losses in cables used for testing.  Check also your wattmeter frequency calibration curve. Do not be too ready to condemn the
transmitter or the RF feedline & antenna installation.