CALAMP WIRELESS NETWORKS INC. BDD4T881 Manual Do Utilizador

Página de 66
120 20170-200
Paragon
PD
 Technical Manual
22
Use this field to enter user-convenient de-
scription(s) (customer name, location,
etc…).
2-  Press the button “Put Comments” to make
the entry permanent. This field may be left
blank.
On subsequent Connect, this field displays en-
tered comments. If no comment was entered, the
field will remain blank.
4.4.3.3 Password
The password feature is useful where two (or
more) fleets share the same radio channel. Mo-
biles without the proper password would still
receive the message but the contents would not
be intelligible.
1-  Type your password directly in the “Pass-
word” field. It is a string of 32 hexadecimal
characters (exactly).
2-  Press the button “Put Password” to make the
entry permanent. This field may be left
blank.
On subsequent Connect, this field will require
that the correct password be entered. If none was
entered, the field will remain blank.
Password information is NOT retrieved and
saved to a file, along with the configuration.
Clearing a Password is done by entering 32 zeros.
The Dataradio supplied password algorithm is
designed to thwart the casual observer only. It
provides a limited form of data privacy. There-
fore, if your security requirements are high, Da-
taradio urges you to use external encryption
technology such as Data Encryption Standard
(DES) in the Host and Mobiles computers.
4.4.4 Test 
Functions
The following RIS functions and buttons are
used to carry out testing or trouble-shooting on a
connected unit:
  TXON (Modulated) button
  TXON (Unmodulated) button
  Flatness test button
  Random data test button
   Ping Address and Ping button
Note:
While a button is in-use for test trans-
missions, all others are inoperative.
4.4.4.1 Channel 
Selection
Paragon
PD
 uses its default radio channel. No
channel selection being available, all channels
are grayed-out.
4.4.4.2 TXON 
Tests
4.4.4.2.1 Unmodulated 
Carrier
Unmodulated carrier gives a clear carrier and is
frequently used for checking:
  Frequency error
  Forward and reflected power
Press the TXON (Unmodulated) button to trans-
mit an unmodulated test signal for 30 seconds on
its default channel or until pressed again.
The time remaining to test transmit is displayed
on the status bar.
4.4.4.2.2 Modulated 
Carrier
Test transmission generates a carrier modulated
with a test tone at a speed and a deviation level
that depends on network speed as detailed in
Table 8 below.