CALAMP WIRELESS NETWORKS INC. BDP3-CRE700 Manual Do Utilizador

Página de 72
 
 
120 20194-102 
 
Paragon3 – 700/800MHz User Manual
 
26
4.7.3  Setup (Advanced)  
4.7.3.1 Setup 
(Advanced) 
► LAN (IP) 
Allows the setting of IP characteristics beyond those set in “Setup (Basic)”
 Î “Basic 
IP”. 
When a mobile registers with a new base, the base may send a message to each of its neighbor to 
assure that their Internet tables are up-to-date. Up to 32 neighbors can be entered. An empty or 
incomplete table may cause IP routing problems when the mobile roams.
 
 
Figure 25 - Advanced IP Configuration - LAN (IP) 
Item 
Description 
IP Address 
Netmask 
Read-only fields showing “IP Address” and “Netmask address” defined earlier in 
“Setup (Basic)” 
Π“Basic IP”. 
MTU 
Ethernet Interface MTU - Default 1500. –  For optimal performance, set at 1500. 
Entering a value lower than 1500 may reduce system performance. Flexibility of us-
ing lower values may be useful in testing or for particular operational conditions.  
Range is 576 to 1500. 
Interfa
ce 1 (E
TH
1) 
MAC address 
Ethernet Interface MAC address in HEX format (factory-set)
IP Address 
Set to valid unique IP address for each individual unit.  
Factory default is 192.168.203.1 for all Paragon3 units connected to their ETH2 port. 
For ETH1 configuration, see Setup Basic 
ΠBasic IP Configuration   
Netmask 
Set to valid IP netmask for each individual unit (may be same or different depending 
on customer’s IP network topology)
MTU 
Ethernet Interface MTU - Default 1500. –  For optimal performance, set at 1500. 
Entering a value lower than 1500 may reduce system performance. Flexibility of us-
ing lower values may be useful in testing or for particular operational conditions.  
Range is 576 to 1500. 
Interfa
ce 2  
(ETH2
MAC address 
Ethernet Interface MAC address in HEX format (factory-set)
Add 
Type in the “Neighboring Bases” field the IP address in dot decimal format of the 
base to be added to the neighboring “Base List” table. 
Delete 
Type in the “Neighboring Bases” field the IP address in dot decimal format of the 
base to be deleted from the neighboring “Base List” table. 
Neigh
bori
ng 
Bases 
Base List 
Read-only listing. Dynamic window expands downward as needed to show all ad-
dresses added to the list or shrinks as addresses are removed.