Itron Inc. 100TGGRD Manual Do Utilizador
Installing the Itron GasGate RD
TDC-1345-000 GasGate™ Remote Disconnect (RD) Installation Guide
7
Proprietary and Confidential
To connect the GasGate RD
1. Using the handheld computer loaded with FDM Endpoint Tools, select Number 2 Connect Service.
2. Click Next. Enter the GasGate ID.
3. Click Next.
2. Click Next. Enter the GasGate ID.
3. Click Next.
Note A Warning appears to remind the service technician to light pilots after the valve is opened.
Caution You must wait until the handheld confirms the valve is ready to be opened. If you attempt to
open the valve before the handheld confirms a valve ready state, the valve will return a failed status and
initiate a tamper event.
4. Using the GasGate valve tool, turn the valve bolt to lock the valve into the open position.
Important Turn the valve tool until you hear a click indicating the valve locked into place.
In the event the valve operation is not confirmed, an error message (Result of operation is inconclusive:
In the event the valve operation is not confirmed, an error message (Result of operation is inconclusive:
the endpoint was not found) appears.
To disconnect the GasGate RD
1. In FDM Endpoint Tools, select number 3 Disconnect Service.
2. Enter the GasGate ID. Select Next.
2. Enter the GasGate ID. Select Next.
Note A warning appears: You are turning off the gas supply.
3. Click Next to proceed.
A confirmation screen appears indicating the valve is closed. If the valve does not confirm a status of
closed, an error screen will appear. Repeat the process. If the valve does not confirm a closed status after
the second try, call Itron Technical Support for help.
To decommission the GasGate RD
Warning Prior to decommissioning, verify the gas supply is turned off.
1. In FDM Endpoint Tools, select number 5 Decommission. Click Next.
2. Enter the GasGate ID. Click Next.
2. Enter the GasGate ID. Click Next.
A screen appears confirming the GasGate is decommissioned.