Itron Inc. 100WD Manual Do Utilizador

Página de 11
 
TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 
39  
 
Proprietary and Confidential 
 
 
 
 
This section describes the 100W/100W+ and 100WP/100WP+ ERT module connections to the water meter 
register using the inline connector assembly. Follow the manufacturer's recommended procedure for installing 
the water meter register on the meter. 
 
To connect the inline connector 
Note  If an inline connector is not used and the ERT module is already connected to the water meter register, 
skip this step. 
1.  Remove the protective cover from the connector by twisting the two halves in opposite directions. Pull the 
halves apart. 
 
 
Caution  Verify the connector halves are clean and dry before assembly. 
If any of the following conditions occur, do not install the ERT modules:  
   •   Any of the three pins are damaged or missing. 
   •   The O-ring is missing. 
   •   The cable is cut or nicked. 
2.  Connect the register cable to the ERT module connector:  
  Holding the connectors by the black shells, rotate one end to align the keyed slots. 
  Push until snug.  
  Slide the black coupling nut over the O-ring. Make sure the O-ring stays seated. (If the O-ring does 
not stay seated, disconnect and repeat this step.) 
  Twist the register cable's black coupling nut to align the two tabs. 
 
A
P P E N D I X  
A  
Using an Inline Connector