Digital Security Controls Ltd. 005132XS433 Manual Do Utilizador

Página de 28
1
This manual describes how to install, program and maintain the PC5132.
Before you install the PC5132 module, you should have completed the following
steps in your system installation:
1. Plan the installation and wiring of the security system (see your system
Installation Manual)
2. Install the control panel, and install and enroll at least one keypad to use
for programming.
3. Install and enroll any hardwired zone expander modules (PC5108) you
plan to use.
NOTE: PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g.
zones 9-12 and zones 13-16). None of the zones assigned to a PC5108 mod-
ule may be used for wireless devices.
Program the PC5132 from a system keypad or using downloading software on
a remote computer (e.g., DLS-3). Read your system 
Installation Manual for more
information.
1.1 How to use this Manual
Read this manual before you begin installing the PC5132. To install and set up the
PC5132 and wireless devices, follow these steps. Refer to the sections listed below.
1. Temporarily mount  and wire the PC5132 module (see 
Section 2)
2. Enroll and program wireless devices (see 
Section 3)
3. Complete zone and other programming on the system (see 
Section 4)
4. Test the placement of all the wireless devices 
(see Section 5)
5. Permanently mount the PC5132 receiver and wireless devices 
(see Section 5)
For additional information on trouble conditions, RF jamming signal detection and
battery replacement, see 
Section 6.
For help with troubleshooting, see 
Section 7.
1.2 Specifications and Features
• Current Draw: 40mA
• Frequency: 433 MHz
• Zones - receiver can receive signals from up to 32 wireless zones and 16
wireless keys
• Internal antenna
• Supervisory - programmable supervisory window, 2 to 24 hours, in 15
minute increments
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire;
the wiring used in this circuit connection must be insulated with PVC, TFE,
PTFE, FEP, Neoprene or Polymide
- connects to Keybus
- for longer wire runs, thicker gauge wire must be used.
• Compatibility: The PC5132 v5.X can be connected to the following panels:
PC5020, PC501X, PC1565, PC585
S E C T I O N  1