Digital Security Controls Ltd. 005501Z32433 Manual Do Utilizador

Página de 32
11
E N R O L L  &  P R O G R A M  D E V I C E S
Command Output Activation
NOTE: The Identified Wireless Key Command Output Activation feature is only
available with the PC5010, PC5015, PC5008, PC1555 and PC580 v2.0 and higher.
To enable command output activation by wireless keys, do the following:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Enable the PGM output attribute 
Requires Access Code
 for each PGM output
programmed as [✱][7][1-4] in sections [141] to [154].
3.5 Deleting Wireless Devices
To remove a wireless device from the system, follow the guideline for adding a
wireless device. Program the ESN as [000000]. The wireless device for the zone
will be removed.
NOTE: You may need to remove power from the panel in order to clear troubles
caused by deleted zones.
Now that you have enrolled all the wireless devices, you will need to program the