Digital Security Controls Ltd. 00NB9001 Manual Do Utilizador

Página de 34
C h a n g i n g   H o w   t h e   N T 9 0 1 0   W o r k s   F o r   U s e r s :   4 . 1 1   P r o g r a m m i n g   W i r e l e s s   K e y s   a n d   H a n d h e l d   K e y p a d s
13
[10] - [
*
]+[3] Alarm Memory
This function key provides the user with a simple method for 
entering the Alarm Memory Display Mode (see section  “[*] [3] 
Alarm Memory” 
on page 11).
[11] - [
*
]+[5] Programming Access Codes
This function key provides the user with a simple method for pro-
gramming access codes. After this key is pressed a valid System 
Master or Supervisor Code will have to be entered before the sys-
tem will allow programming to be performed (see section  “[*] 
[5] Programming Access Codes” 
on page 11).
[12] - [
*
]+[6] User Functions
This function key provides the user with a simple method for pro-
gramming User Functions. After this key is pressed a valid System 
Master or Supervisor code must be entered before the system 
will allow User Functions to be performed (see section  “[*] [6] 
User Functions” 
on page 11).
[13] - [15] For future use
[16] - [
*
]+[0] Quick Exit
Pressing this key will cause the system to activate the Quick Exit 
feature (see section  “[*] [0] Quick Exit” on page 12).
[17] - [
*
]+[1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for 
adding Stay/Away zones back into the system (see section  “[*][1] 
Zone Bypassing” 
on page 10).
[18] - [26] For future use
[27] - Status
Press and hold this key for two seconds to have the NT9010 
announce the current status of the system. For example, the sys-
tem may announce:
“Zones are open. Zone 1. Secure system before turning on. For 
more options, press star.” 
[28] - Volume
To change the volume of NT9010 announcements, press and 
hold this key for two seconds. The NT9010 will announce the dif-
ferent volume levels. 
[29] - Record
Press and hold this key for two seconds to begin recording a 
message through the NT9010 microphone. After you hear the 
prompt “Record Memo Now” and a single 1s tone, begin record-
ing your message. When you are finished recording, press [#].
[30] - Playback
Press and hold this key for two seconds to listen to a recorded 
message. If there is no message recorded, the NT9010 will sound 
an error tone. You can stop playback of the recorded memo any 
time by pressing [#].
4.11 Programming Wireless Keys and 
Handheld Keypads
If you will be adding WLS909 wireless keys, or WLS910 handheld 
keypads, after you enroll them on the system, 
you may want to 
change the function of the buttons on these devices
.
If you enable the WLS Key Does Not Use Access Codes option, 
the disarm button will work on wireless keys which have not 
been assigned access codes. To prevent disarming by wireless 
keys which don’t have access codes, disable this option.
To change wireless key or handheld keypad function buttons, 
from Advanced Programming:
1. Enter section [804].
2. Enter the 2-digit sub-section number of the button you want 
to program:
[57] = Handheld keypad button 1
[58] = Handheld keypad button 2
[59] = Handheld keypad button 3
[60] = Handheld keypad button 4
[61] = Wireless key button 1
[62] = Wireless key button 2
[63] = Wireless key button 3
[64] = Wireless key button 4
3. Enter the 2-digit code from the list below for the function you 
want the button to have:
4. Repeat steps 1 to 3 until all buttons are programmed.
Handheld Keypad Function 
Button Programming. . . . . . . . Sections [804]-[57] to [804]-[60]
Wireless Key Function 
Button Programming. . . . . . . . Sections [804]-[61] to [804]-[64]
WLS Key Does Not Use Access Codes  .Section [017], Option [1]
4.12 Fire, Auxiliary, and Panic Keys
The emergency keys are available on the NT9010. Each pair of 
keys must be pressed and held for 2 seconds before they will 
activate. This 2 second delay is designed to help prevent acciden-
tal activation.
If the Fire Keys option is enabled, when the Fire keys are pressed 
and held for 2 seconds, the system will activate the alarm output. 
It pulses one second on, one second off only if option 8 of Sec-
tion [013] is disabled (Standard Fire option). If Fire Bell Continu-
ous
 is selected the alarm output will sound until a code is 
entered, otherwise it will sound until a code is entered or the 
alarm output times out. Communication of the signal to central 
station is immediate.
If the Auxiliary Keys are pressed and held for 2 seconds the sys-
tem will sound the keypad beeper three times to verify activation. 
The system will beep the keypad ten times rapidly to verify com-
munication to the central station.
If the Panic Keys are pressed and held for 2 seconds, the system 
will immediately communicate the signal to central station. If 
Entry
Description
Can Be Used 
on Handheld 
Keypad
Can Be Used 
on Wireless 
Key
00
Null Key (Key not used)
Yes
Yes
03
Stay Arm
Yes
Yes
04
Away Arm
Yes
Yes
05
No entry delay arming
Yes
No
06
Door Chime On/Off
Yes
Yes
07
System Test
Yes
Yes
16
Quick Exit
Yes
Yes
17
Activate Stay/Away Zones
Yes
Yes
27
Disarm (Off)
No
Yes
28
FIre Alarm
No
Yes
29
Auxiliary Alarm
No
Yes
30
Panic Alarm
No
Yes
31
Status
Yes
Yes