By enabling Tampers/Faults Do Not Show as Open, faults and tampers for wire-
less zones will not be annunciated, and will be hidden from the end user. If the 
option is disabled, faults and tampers will be annunciated.
NOTE:
Once a zone is tampered or faulted, it must be completely 
restored before the trouble condition will clear.
If the All System Tampers Require Installer Reset option is enabled, any zone 
faults must be reset by entering [✱][8][Installer’s Code] before the system can be 
armed. Auto-Arming and Keyswitch arming will also be prevented in the presence 
of any zone fault.
NOTE:
 The Auto Arm cancellation code will not be transmitted if arming 
is inhibited due to a zone fault.  The Auto Arm cancellation code will be 
transmitted if arming is inhibited due to Latching Tamper.
Tampers/Faults Do Not Show As Open . . . . . . . . . . . . . . .  Section [013], Option [4]
All System Tampers Require Installer Reset . . . . . . . . . . . .  Section [701], Option [4]
2.3.8
Communicator 
Dialing
If the Communicator Disable option is selected the system will never attempt to 
call central station. If the Communicator is enabled, the system will attempt to call 
central station when an event occurs that has a valid reporting code programmed 
(see 2.3.12 CommunicatorReporting Codes on page 47). You must also pro-
gram a valid telephone number for the communicator to work.
Communicator Call Direction Options are used to select where the system will 
send different kinds of reporting codes when events occur. You can choose to have 
the system send reporting codes to:
• 1st telephone number 
• 2nd telephone number
These options are programmed separately for each type of reporting code.
The different types of reporting codes are:
• Alarm/Restore codes
• Tamper Alarm/Restore codes
• Opening/Closing codes
• System Maintenance Alarm/Restore codes
• System Test Transmission codes
When the Force Dialing option is enabled, the system will dial out regardless of 
the presence of dial tone. Each dialing attempt will follow this pattern: 
a) the system picks up the telephone line and searches for dial tone for 5 seconds 