I N S T A L L A T I O N
4. Each PGM output is an open collector switch to ground. That is,
when the PGM output is activated by the RF5501-433 the terminal
will switch to ground. P1 can sink up to 50 mA of current to
activate LEDs or a small buzzer. Connect the positive side of
the LED or buzzer to AUX+, the negative side to P1. If more than
50 mA of current is required a relay must be used. Please refer
to diagram.
will switch to ground. P1 can sink up to 50 mA of current to
activate LEDs or a small buzzer. Connect the positive side of
the LED or buzzer to AUX+, the negative side to P1. If more than
50 mA of current is required a relay must be used. Please refer
to diagram.
1.4 Applying Power
Once all wiring is complete, apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the control panel
Installation Manual.
Installation Manual.
NOTE: Do not connect the power until all wiring is complete and unit is securely mounted.
1.5 Enrolling the Keypad
Once all wiring is complete, you will need to enter a 2-digit number that tells the
system the partition and slot assignment of the keypad.
system the partition and slot assignment of the keypad.
If your system has partitions, you will also need to assign the keypad to a partition
(1st digit).
(1st digit).
The slot assignment (2nd digit) tells the panel which keypad slots are occupied. The
panel can then generate a fault when a keypad supervisory signal is not present. There
are eight available slots for keypads. RF5501-433 keypads are always assigned to slot
1 by default. You will need to assign each keypad to its own slot (1 to 8).
panel can then generate a fault when a keypad supervisory signal is not present. There
are eight available slots for keypads. RF5501-433 keypads are always assigned to slot
1 by default. You will need to assign each keypad to its own slot (1 to 8).
NOTE: The RF5501-433 enrolls as two modules:
1 = keypad section of the RF5501-433
17 = receiver section of the RF5501-433
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [*][8][Installer’s Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot assignment.
NOTE: If your system does not have partitions, enter [1] for the first digit.
1st digit
Enter 0 for Global Keypad, 1-8 for keypad partition
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
2nd digit
Enter 1 to 8 for Slot Assignment
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory reset by entering [*][8][Installer’s
Code][902]. The panel will now supervise all assigned keypads and enrolled
modules on the system.
modules on the system.
RF5501-433
R
B
Y
G
P
1
P
2
/
Z
RED
COM
WHT
YEL
GRN
NC
NO
BLK
DSC
RM-1