Digital Security Controls Ltd. 09LC151 Manual Do Utilizador

Página de 16
 
12 
 
Environment type 
Potentiometer position 
MW jumper position 
Low risk 
At position 5 
Risk 
Between positions  
3 and 4    
H
 
High risk 
Between positions  
4 and 5 
Very high risk 
Between positions  
3 and 4 
Noisy area 
Between positions  
2 and 3 
Extremely Noisy area 
 At position 1 
 
Note: Adjust sensitivity according to environmental conditions! 
• Low 
risk: very stable environment without interference from parking garages, parking 
space, playgrounds, football fields, service roads, etc. 
• Risk: Stable environment with some trees, bushes, flowerpots, planters, etc.  
• High 
risk: Unstable environment with different types of vegetation and grass and 
puddles. 
•  Very high risk: Unstable environment with winds and small pets, rats, mice, birds. 
• Noisy 
area: Unstable environment with vegetation and water sources like swimming 
pool, lake, canal, weeds as well as small pets like cats and rabbits. 
• Extremely 
Noisy 
area: Very unstable environment subjected to wind, snow, rain, with 
vegetation, water and large pets like dogs. 
For Example: 
If the detector is used in a space which contains several bushes and a swimming pool the 
environmental conditions should be considered a "Noisy Area" 
 
8.3 Indications 
setting 
 
The LC-151 has 3 LEDs that each points at different indication:  
1.  Green LED indicates PIR detection. 
2.  Yellow LED indicates Microwave detection. 
3.  Red LED – Indicates an alarm (logic AND of both Mircowave and PIR).