Digital Security Controls Ltd. 18PG9307 Manual Do Utilizador

Página de 4
D-307315
PG9307 PowerG recessed
door/window contact
The PG9307 is a discreet, supervised, 2- way wireless
PowerG magnetic contact device.
The PG9307 uses a replaceable lithium battery and
should last 10 years under normal usage.
Legend
Figure 1.
A
B
B
C
D
E
Recessed door/window contact
A Door / window contact housing
B Breakable screw ears
C Contact cover and circuit board
D Magnet cover
E Magnet with double- sided tape
Inserting or replacing the battery
CAUTION! This product uses lithium batteries.
Improper handling of lithium batteries may result in
HEAT GENERATION, EXPLOSION or FIRE, which
may lead to personal injuries.
WARNING! Danger of explosion if batteries are
installed incorrectly. Replace only with the same or
equivalent type recommended by the manufacturer.
Dispose of used batteries according to the man-
ufacturer's instructions and according to local rules
and regulations.
Keep away from small children: if swallowed
promptly see a doctor.
Do not try to recharge these batteries.
NOTE: Battery replacement should be done by an
installer.
1.
Insert a small, flat-head screwdriver into the slots
on the side of the contact housing and release the
contact cover.
2.
Pull out the cover from the door/window contact
housing.
3.
Observe the polarity and insert or replace the bat-
tery.
4.
Reinsert the contact cover (with circuit board
attached).
Enrollment
Refer to the panel installation manual for the enroll-
ment procedure.
A general description of the procedure is provided in
the following flow chart:
Step
Procedure
1
See the Installation Manual for the alarm sys-
tem that the device is being enrolled on to
ensure that the proper steps are used.
2
Enter the device enrollment option through
the specified method and select the appro-
priate option to add the new device.
3
Insert the battery and wait for the panel to
detect the device or enter the device ID.
4
Select the desired zone number.
5
Configure any device parameters that are
required.
6
Mount and test the device. See Placement
Testing for information on testing the
device. In addition, see the alarm systems
Installation Manual that the device is
enrolled on for other test procedures that
are required.
Performing a placement test
Before you permanently mount any wireless device,
temporarily mount the device and perform a place-
ment test on the door frame, as close as possible to the
planned installation area. This is for checking the
radio link.
1.
To tamper the device, pull the cover attached to
the device.
2.
Reinsert the cover to restore the tamper. The
device now enters placement test mode for 15
minutes.
3.
Trip the device by opening the door or window
and verify that the red LED blinks, indicating
detection.
After 2 seconds the LED blinks 3 times. The following
table indicates the received signal strength.
LED Response
Signal Strength
Green LED blinks
STRONG
Orange LED blinks GOOD
Red LED blinks
POOR
No blinks
No communication
IMPORTANT! Only GOOD or STRONG signal
strengths are acceptable. If you receive a POOR sig-
nal from the device, re-locate it and re- test until a
GOOD or STRONG signal is received.
NOTE: For UL/ULC installations, only STRONG sig-
nal levels are acceptable. After installation verify the
product functionality in conjunction with the com-
patible control panels HSM2HOST9, HS2LCDRF(P)9,
HS2ICNRF(P) 9, PG9920, WS900-19, and WS900- 29.
NOTE: For detailed Placement instructions refer to
the control panel reference manual.
Installation tips
WARNING:
To comply with FCC and ISED Canada
RF exposure compliance requirements, the contact
should be located at a distance of at least 20 cm from
all persons during normal operation. The antennas
used for this product must not be co-located or oper-
ated in conjunction with any other antenna or trans-
mitter.
NOTE:The PG9307 PowerG recessed door/window
contact shall be installed and used within an envir-
onment that provides the pollution degree max 2 and
overvoltages category II in NON HAZARDOUS
LOCATIONS. The equipment is designed to be
installed only by qualified service persons.
It is recommended to install the contact in the door
frame and the magnet in the door.
NOTE:Before drilling holes, test the location. Tem-
porarily mount the contact and magnet and perform a
placement test.
Once drilled, the signal quality may be impacted.
Gap separation
The following table outlines the gap separation inform-
ation.
Nonmetallic wood/plastic materials
Direction of move-
ment
of the magnet
Approach/Make
Remove/
Break
Axis X
15 mm
17 mm
Axis Y
15 mm
17 mm
Axis Z
23 mm
28 mm
The recommended maximum gap separation for
installation (on specified materials and Axis Z) is 6
mm (0.24 in.).
Figure 2.
Mounting the device
NOTE: There are various ways to mount the device.
This procedure outlines one option for installation.
Allow 3mm minimum between the door and frame.
Figure 3: Mounting the recessed door/window contact
B
A
C
Door frame
Recessed door/window contact
Screws
Figure 4: Mounting the magnet
A
B
Door
Magnet
Install the device in the door frame, and install the
magnet on the door. Install the device and magnet on
either the side or the top of the door and the door
frame.
Figure 5.
Mark the locations for the door/window contact and
the magnet. Ensure that the locations for the contact
and the magnet are correctly aligned.
Sensor installation.
Install the sensor by the following steps:
1.
Use a 3/4 drill bit to slowly drill a 3/4 inch hole for
the door/window contact in the door frame.
2.
Fasten the contact housing to the mounting surface
with the two screws and insert the cover. If there
is no 3mm gap available between the door and the
frame, two step drilling is necessary. Using a
22mm tool, drill a 2mm shallow, followed by a
70mm deep hole with a 19mm tool. Break the slot
ears, clean the sharp edges and insert the device.
The device is recessed inside the frame, not inter-
fering with the door.
Figure 6: Sensor installation
 3/4 in ( 
19.05 mm) 
 2.68 in 
(68 mm)
 0.6 in 
(15 mm)
 0.08 in 
2 mm
Device/Frame
Magnet/Door
 7/8 in (
22.2 mm) 
Magnet installation.
Install the magnet by either of the following options:
1.
By drilling:
a.
Use a 3/4 inch drill bit to create a 15mm deep
hole.
b.
Peel off the double-sided tape on the magnet
and stick it inside the magnet cover (part D).
2.
By using the double-sided tape without the magnet
housing:
a.
Peel off the double-sided tape on the magnet
and stick it on the door/window.
NOTE: Option 2 is possible only when there is a min-
imum gap of 2 mm between the door and the door
frame.
Optional: Use a sticker on both the contact cover and
the magnet cover to match the color of the door or the
door frame.
Specifications
Frequency
912 MHz to 919 MHz
Communication
protocol
PowerG
Maximum
power
+14 dBm
Battery type
Panasonic or GP, 3V CR-2 or equi-
valent lithium battery
Battery life
expectancy
10 years (with typical use)
Battery
supervision
Automatic transmission of battery
condition data as part of periodic
status report and immediately upon
low battery condition detection.
Low battery
trouble level
2.5 V
Temperature
range
-10 °C to 50 °C
Relative
humidity
5% to 95% non condensing
Magnet type
Rare earth
Contact size
(HxD)
2.66 inches x 0.75 inches
Magnet cover
size (HxD)
0.67 inches x 0.08 inches
Weight (with
battery and
magnet)
0.83 oz (25 g)
Color
White or clear
Housing
material
Polycarbonate
Figure 7.
Compatible receivers
This device can be used with DSC panels and receiv-
ers that use PowerG technology.
UL/ULC Not es
Only model PG9307 operating in the frequency band 912-
919MHz is UL/ULC listed. The PG9307 has been listed by
UL for commercial and residential burglary applications and
by ULC for residential burglary applications in accordance
with the requirements in the Standards UL 634 and ULC
ORD-C634for Intrusion Detection Units.
For UL/ULC installations use these device only in con-
junction with compatible DSC wireless receivers:
HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920,
WS900-19, and WS900-29. After installation verify the
product functionality in conjunction with the compatible
receiver used.
FCC COM PLIANCE STATEM ENT
WARNING! Changes or modifications to this unit not
expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reas-
onable protection against harmful interference in residential
installations. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful inter-
ference to radio and television reception.
However, there is no guarantee that interference will not
occur in a particular installation. If this device does cause
such interference, which can be verified by turning the
device off and on, the user is encouraged to eliminate the
interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from
the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
FCC ID: F5318PG9307
Innovation Science and Economic Development
Canada (ISED) Statement
This equipment complies with FCC and ISED Canada RF
radiation exposure limits set forth for an uncontrolled envir-
onment.
This device complies with FCC Rules Part 15 and with
ISED Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device
must accept any interference that may be received or that
may cause undesired operation.
Le present appareil est conforme aux CNR d'ISED Canada
applicables aux appareils radio exempts de licence. L'ex-
ploitation est autorisee aux deux conditions suivantes :(1)
l'appareil ne doit pas produire de brouillage, et (2) l'util-
isateur de l'appareil doit accepter tout brouillage radi-
oelectrique subi, meme si le brouillage est susceptible d'en
compromettre le fonctionnement.
IC: 160A-PG9307
Limited Warranty
Digital Security Controls (DSC) warrants that for a period of
twelve months from the date of purchase, the product shall
be free of defects in materials and workmanship under nor-
mal use and that in fulfilment of any breach of such war-
ranty, DSC shall, at its option, repair or replace the
defective equipment upon return of the equipment to its
factory. This warranty applies only to defects in parts and
workmanship and not to damage incurred in shipping or
handling, or damage due to causes beyond the control of
DSC such as lightning, excessive voltage, mechanical
shock, water damage, or damage arising out of abuse, alter-
ation or improper application of the equipment.
The foregoing warranty shall apply only to the original
buyer, and is and shall be in lieu of any and all other war-
ranties, whether expressed or implied and of all other oblig-
ations or liabilities on the part of DSC. This warranty
PG9307 PowerG recessed door/window contact Installation Instructions
©2017 Tyco Security Products, Toronto, Canada www.dsc.com Tech. Support: 1-800-387-3630
1