ADC Telecommunications Inc. DNYSMR1A Manual Do Utilizador

Página de 38
ADCP-75-187 • Issue 1 • September 2005 • Section 2: DESCRIPTION
Page 2-19
© 2005, ADC Telecommunications, Inc.
Table 2-6. Interim Single-Band Remote Unit Nominal Specifications
PARAMETER
SPECIFICATION
REMARKS
Physical/Environmental/
Electrical - Remote Unit
Dimensions (L
×W×D)
37.3 
× 10.2 × 7.5 inches
(947 
× 259 × 191 mm)
Mounting
Pole, wall, or strand mounted
Requires accessory kit for strand 
mounting
Weight
79.5 lbs. (36.1 kg)
With solar shields installed
Weather resistance
NEMA 4X, IEC IP 67
Indoor or outdoor installation
Lightning protection
20 kA IEC 1000-4-5 8/20 µs 
waveform
With external protector (acces-
sory)
Operating temperature
–30º to 50º C (–22º to 122º F)
Storage temperature
–40º to 70º C (–40º to 158ºF)
Humidity
10% to 90%
No condensation
AC power connector
Mini 3-pin
3-wire power cable included
Antenna connector(s)
50 ohm N-type (female)
50 ohms input/output impedance
Optical port
OptiTap with APC/SC connector 
and adapter
Voltage input
90 to 265 VAC, 47 to 63 Hz
60 to 89 VAC, 47 to 63 Hz
Standard
Option
Power consumption
150 Watts
Current rating
1.25 Amps at 120 VAC
.625 Amps at 240 VAC
Reliability at 25ºC
MTBF - 80,000 hours