ADC Telecommunications Inc. PRSM074C Manual Do Utilizador

Página de 138
Viewing Remote SeRF Optical Ports
FlexWave Prism Host, Remote and EMS 5.1 System Reference
Page 249
ADCP-77-073
  • Issue 2 • 11/2009
© 2009 ADC Telecommunications, Inc.
The
Optical Ports On Remote
-n view provides an alarm summary for the SeRF card on 
the identified Remote. 
Optics  Number
—System-assigned port number and link to the 
Port  Configuration 
Page
 for this particular port
Optics Name
—User-entered port name or 
UNKNOWN_SFPName
 indicating no name 
has been entered
Ip Enable
—Disabled for Remotes. This parameter indicates if the link is carrying IP 
traffic. It can only be set on the Host as described in 
“Configure the Remote SeRF 
Optical Ports” on page 158
.
Optics Type
—Laser range, which is 
LongRange 
to meet 3Gbps optical transmission 
requirements.
Fwd Launch
—Launch power in dB of REV path signal, from the Remote to the Host.
Rev Receive
—Launch power in dB of receive level of the FWD path, from the Host 
to the Remote. The minimum REV launch power is -27 dBm, and the maximum is 
-9 dBm.
Wave Length
—Number displayed is wave length transmitted through this port
RxBer  Fault
—Yellow indicates that there ware too many errors on the receiving 
fiber. Fault threshold is 
0.00001
.
RxNoLight Fault
—Red indicates that no light is detected on the receiving fiber
Laser Fault
—Red indicates reverse path laser is not sending light
OverDrive  Fault
—Red indicates forward path optical signal is too strong. Fault 
threshold is 
-9dBm
.
UnderDrive  Fault
—Yellow indicates forward path optical signal is too weak. The 
underdrive is from -28dBm to -33dBm. Fault threshold is 
-27dBm
.
Host Name
—Name of the Host at the other end of the fiber.