ADC Telecommunications Inc. PRSM074C Manual Do Utilizador
Managing Alarms
Page 266
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
• Issue 2 • 11/2009
HostModuleMissingFault
Major
One of the pluggable
modules is missing
on the Host
modules is missing
on the Host
Either insert a
replacement unit or
decommission the
unit
replacement unit or
decommission the
unit
HostOverTempFault
Major
The temperature of
the Host is Over its
upper limit of 84C
the Host is Over its
upper limit of 84C
Check Host fan and
ambient conditions
ambient conditions
HostSERFFault
Major
Summary fault for
SeRF combining
SeRF synthesizer
and SeRF FPGA
status. Either the
clock source is not
acceptable or the
SeRF board FPGA is
not programmed.
SeRF combining
SeRF synthesizer
and SeRF FPGA
status. Either the
clock source is not
acceptable or the
SeRF board FPGA is
not programmed.
Check for related
SeRF alarms in
SeRF alarms in
Active Alarm List
and respond to
those alarms if
found. If no SeRF
alarms exists, FPGA
is faulty; consult
ADC, replace SeRF. If
SeRF is replaced, use
the same Compact
Flash to retain
system
configuration.
those alarms if
found. If no SeRF
alarms exists, FPGA
is faulty; consult
ADC, replace SeRF. If
SeRF is replaced, use
the same Compact
Flash to retain
system
configuration.
HostSERFOptOverDriveFault
Major
The power of the
signal received from
the Remote exceeds
the maximum level
of -9dBm
signal received from
the Remote exceeds
the maximum level
of -9dBm
Externally attenuate
Remote return path
signal or replace
Remote SFP with one
of less strength
Remote return path
signal or replace
Remote SFP with one
of less strength
HostSerfOptRxBerFault
Minor
Too many errors on
the receiving fiber
the receiving fiber
Check fiber for kink
or sharp bend. Check
for too much gain.
Make sure the fiber
is clean.
or sharp bend. Check
for too much gain.
Make sure the fiber
is clean.
HostSERFOptRxNoLightFault
Major
No light detected
from the receiving
fiber
from the receiving
fiber
Check for broken or
disconnected fiber.
Check for out of
service Remote
disconnected fiber.
Check for out of
service Remote
HostSERFOptUnderDriveFault
Minor
The power of the
signal received on
the fiber is below the
minimum power
level of -27dBm
signal received on
the fiber is below the
minimum power
level of -27dBm
Check fiber for too
much attenuation,
dirty connectors.
Check SFP type
being used (too
weak for range)
much attenuation,
dirty connectors.
Check SFP type
being used (too
weak for range)
HostSERFRmtLostFault
Major
Host is not receiving
messages from
connected Remote
or there is an IP
conflict causing loss
of communication
messages from
connected Remote
or there is an IP
conflict causing loss
of communication
Check for optics
disconnect. Check
for Remote out of
power or out of
service
Check for IP conflict
disconnect. Check
for Remote out of
power or out of
service
Check for IP conflict
Table 11-1. EMS Alarm Descriptions and Corrective Actions (Cont.)
Alarm Name
Alarm
Severity
Level
Severity
Level
Description
Action