12.7
T
RAPS
The EMS receives traps from SNMP agents and converts them to alarms and 
non-alarmed events for further processing and reporting. 
For information on 
GET
/
SET
 objects, see 
“FlexWave-URH Agent MIB” on page 292
.
Table 12-3. FlexWave-URH Agent MIB Traps
Trap Object
Description
fwuHstSysCardFanFault
Host System Card Fan fault
fwuHstModuleMissingFault
Host Module missing fault
fwuHstOverTempFault
Host Over Temperature fault
fwuHstUnderTempFault
Host Under Temperature fault
fwuRmtModuleMissingFault
Remote Module missing fault
fwuRmtOverTempFault
Remote Over Temperature fault
fwuRmtUnderTempFault
Remote Under Temperature fault
fwuRmtOpenDoorFault
Door on the Remote is open
fwuRmtFanOverSpeedFault
Remote fan has an Over Speed fault
fwuRmtFanUnderSpeedFault
Remote fan has an Under Speed fault
fwuHstSERFSynthAlarmFault
Onboard synthesizer fault
fwuHstSERFFault
Consolidation of SeRF Onboard synthesizer fault and 
SeRF FPGA Status
fwuHstSERFRmtLostFault
Remote Lost fault-Host not receiving any messages from 
connected Remote
fwuHstSERFOptRxBERFault
Decoded word error state of the primary wavelength 
optical receiver (too many errors)
fwuHstSERFOptRxNoLightFault
Receiving light state of the primary wavelength optical 
receiver (no light)
fwuHstSERFOptLaserFault
Error state of laser forward path
fwuHstSERFOptOverDriveFault
Host SFP Over Drive fault
fwuHstSERFOptUnderDriveFault
Host SFP Under Drive fault
fwuHstSERFOptIpEnableFault
Host SFP IP Enable fault
fwuHstDARTDwnCon1SynLockFault
Lock State of the first Down Converter synthesizer
fwuHstDARTDwnCon2SynLockFault
Lock State of the second Down Converter synthesizer
fwuHstDARTUpConSynLockFault
Lock State of the Up Converter synthesizer
fwuHstDARTOverDriveFault
Host DART Card Over Drive fault. RF signal received from 
BTS is too high