Everspring Industry Co Ltd AD130 Manual Do Utilizador

Página de 2
AD130 
 LAMP MODULE 
 
This plug-in Lamp Module is designed to work with our Passive Infrared Detectors   
SP103 and Door/Window Detectors SM103, serving as a receiver. The AD130 
plug-in Lamp Module is a Z-Wave
TM
 enabled device and is fully compatible with 
any Z-Wave
TM
 enabled network. Z-Wave
TM
 enabled devices displaying the 
Z-Wave
TM
 logo can also be used with it regardless of the manufacturer, and ours 
can also be used in other manufacturer’s Z-Wave
TM
 enabled networks.    Inclusion 
of the Lamp module on other manufacturer’s Wireless Controller menu allows 
remote On/Off control and dimming of lamps connected.  
Each module is 
designed to act as a repeater.    Repeaters will re-transmit the RF signal to ensure 
that the signal is received by its intended destination by routing the signal around 
obstacles and radio dead spots. 
 
 
Adding to Z-Wave
TM
 Network 
 
In the side of the casing, there is an On/Off/Dim knob which is used to carry out 
inclusion, exclusion or association. Put a Z-Wave
TM
 Wireless Controller into 
inclusion/exclusion mode, press the knob on the module to complete the 
inclusion/exclusion process. 
 
 
 
 
 
 
 
 
 
Installation 
 
1.  Plug this Lamp module into a wall outlet near the lamp to be controlled. 
 
2.  Plug the lamp into the Lamp module.  Make sure the lamp to be controlled 
cannot exceed 200 watts. 
 
3.  Turn the knob or switch on the lamp to the ON position. 
 
4.  To manually turn ON the AD130 Lamp Module, press and release the On/Off 
knob. The red indicator LED will turn ON, and the lamp plugged into the AD130 
Lamp module will also turn ON. 
 
5.  To manually turn OFF the AD130 Lamp Module, simply press and release the 
On/Off knob. The red indicator LED will turn OFF and the lamp plugged into 
the AD130 Lamp Module will also turn OFF. 
 
6.  To manually dim the AD130 Lamp Module, press and hold the On/Off knob 
until the desired lighting level has been reached. 
 
7.  If Passive Infrared Detector SP103 or Door/Window Detector SM103 has been 
removed from the wall by triggering the tamper switch, the Detector (SP103 or 
SM103) will send an alarm command (ALARM_REPORT, Alarm Type == 
0x01, Alarm Level == 0x11) 
to the AD130 Lamp Module, of which red 
indicator LED and the lamp plugged into the AD130 Lamp module will flash for 
10 seconds simultaneously. 
 
Programming 
 
The On/Off/Dim knob allows the user 
Turn on, off or dim the lamp attached 
Include or exclude the module from the Z-Wave
TM
 system 
Control other Z-Wave
TM
 enabled devices 
 
See the instructions for SP103 Passive Infrared Detector or SM103 Door/Window 
Detector. 
   
Troubleshooting 
                                   
Symptom 
Cause of Failure 
Recommendation 
The Module not working and 
LED off 
1.  The Module is not 
plugged into the 
electrical outlet 
properly 
2.  The Module is out of 
order 
1.  Check power connections 
2. Don’t open up the Module and 
send it for repair. 
The Module LED illuminating, 
but cannot control the ON/OFF
Switch of the lamp attached 
Check if the lamp plugged 
into the Module has 
burned out 
Replace a new lamp 
The Module LED illuminating, 
but the Detector cannot control
the Module 
1. Not carry out 
association 
2. Frequency interference
1. Carry out association 
2. Wait for a while to re-try