Everspring Industry Co Ltd TR003-01 Manual Do Utilizador

Página de 2
 
Confidential Information of Everspring Industry Co. Ltd
.
 
AD126 
  LAMP MODULE 
 
This  plug-in  Lamp  Module  is  a  transceiver  which  is  a  Z-Wave
TM
  enabled  device 
and  is  fully  compatible  with  any  Z-Wave
TM
  enabled  network.  Z-Wave
TM
  enabled 
devices  displaying  the  Z-Wave
TM
  logo  can  also  be  used  with  it  regardless  of  the 
manufacturer,  and  ours  can  also  be  used  in  other  manufacturer’s  Z-Wave
TM
 
enabled  networks.    Inclusion  of  the  Lamp  module  on  other  manufacturer’s 
Wireless  Controller  menu  allows  remote  On/Off  control  and  dimming  of  lamps 
connected.    Each  module  is  designed  to  act  as  a  repeater.    Repeaters  will 
re-transmit  the  RF  signal  to  ensure  that  the  signal  is  received  by  its  intended 
destination by routing the signal around obstacles and radio dead spots.   
 
Adding to Z-Wave
TM
 Network 
 
In the front casing, there is an On/Off/Dim knob which is used to carry out inclusion, 
exclusion 
or 
association. 
Put 
Z-Wave
TM
 
Wireless 
Controller 
into 
inclusion/exclusion  mode,  press  the  knob  on  the  Module  to  complete  the 
inclusion/exclusion process. 
 
 
 
 
 
 
 
 
 
Installation 
 
1.  Plug this Lamp module into a wall outlet near the lamp to be controlled. 
 
2.  Plug the lamp into the Lamp Module. There are two outlets at different sides of 
AD126. The lamp plugged into the controllable outlet can be controlled by the 
On/Off/Dim  knob  and  remote  controller,  its  maximum  load  is  300  watts.  The 
other  side  acts  as  a  pass-through  outlet  which  is  non-controlled  by  the 
On/Off/Dim knob and remote controller. 
 
3.  Make  sure  the  total  load  of  both  outlets  cannot  exceed  1500  watts  which 
means if the load of controllable outlet is changed; the other pass-through will 
be  altered  accordingly.  For  instance,  if  the  load  of  controllable  outlet  is  about 
300 watts,
 
the other should be 1200 watts. When the load of controllable outlet 
consumes as 0 watts, the other will be 1500 watts. 
 
4.  Turn the knob or switch on the lamp to the ON position. 
 
5.  To  manually  turn  ON  the  AD126  Lamp  Module,  press  and  release  the 
On/Off/Dim  knob.  The  red  indicator  LED  will  turn  ON,  and  the  lamp  plugged 
into the AD126 Lamp Module will also turn ON. 
 
6.  To manually turn OFF the AD126 Lamp Module, simply press and release the 
On/Off/Dim  knob.  The  red  indicator  LED  will  turn  OFF  and  the  lamp  plugged 
into the AD126 Lamp Module will also turn OFF. 
 
7.  To  manually  dim  the  AD126  Lamp  Module,  press  and  hold  the  On/Off/Dim 
knob until the desired lighting level has been reached. 
 
Note:  Dimming  an  inductive  load,  such  as  a  motor  or  a  transformer,  could 
impair the dimmer and load attached as well. 
 
Programming 
 
The On/Off/Dim knob allows the user 
Turn on, off or dim the lamp attached 
Include or exclude the module from the Z-Wave
TM
 system 
Control other Z-Wave
TM
 enabled devices 
 
Advanced Operation 
 
As  long  as  any  Z-Wave
TM
  enabled  device  that  can  send  below  mentioned  alarm 
command 
 
(ALARM_REPORT, Alarm Type == 0x01, Alarm Level == 0x11) 
 
to the AD126 Lamp Module will enable its red indicator LED and the load plugged 
into  the  AD126  Lamp  Module  to  be  on  and  off  intermittently  for  10  seconds 
simultaneously. 
 
Troubleshooting 
                                   
Symptom 
Cause of Failure 
Recommendation 
The Module not working and 
LED off 
1.  The Module is not 
plugged into the 
1.  Check power connections 
2. Don’t open up the Module and 
On /Off / Dim knob 
Controllable outlet 
Pass-through outlet