LOCATING A NODE
About locating nodes
EA_Inspector is capable of locating registered and unregistered REX, REX2 and 
A3 ALPHA node electricity meters.
Note:
Elster recommends disabling EA_Inspector encryption before 
locating a registered or unregistered node, especially utilities 
supporting both unecrypted and encrypted LAN 
communications. See 
 for details on disabling LAN encryption.
Note:
Gas and water modules are battery operated devices that 
remain in a sleeping state until they are awakened (by magnet 
swipe for one-way modules or by receiving a waken signal for 
two-way modules). They cannot be located using the 
Registered Node or Unregistered Node Locator functions.
Accessing node location
menu
To access the Locate Node test menu:
1. From the Main Menu, select 
RF Troubleshooting
.
Figure 6-1. EA_Inspector Main Menu
The RF Troubleshooting menu displays.