Rosslare Enterprises Ltd AYX25B Manual Do Utilizador

Página de 2
AY-x5B Series 
 
MIFARE Classic® EV1 CSN Readers 
Installation Manual 
1.
  Introduction 
The AY-x5B is a series of RFID proximity card readers to be installed for 
use with access control systems. 
The AY-x5B series reads the card serial number (CSN) from MIFARE 
Classic® EV1 credentials (4 UID and 7 UID) and transmits its data to 
the access control system using Wiegand 26-Bit output. 
Other Wiegand formats and the Clock & Data format are available as 
factory configurable options. 
Figure 1: AY-x5B Series 
 
 
 
 
AY-M5B 
AY-H5B 
AY-L5B 
AY-K5B 
2.
  Technical Specifications 
2.1
 
Electrical Characteristics 
Specifications  AY-M5B  AY-H5B 
AY-L5B 
AY-K5B 
Power Supply Type 
Linear (recommended) 
Operating Voltage 
Range 
5–16 VDC 
Absolute Maximum 
(non-operating) 
18 VDC 
Current @ 12V 
Standby: 45 mA 
Maximum: 100 mA 
Max. Read Range* 
6.5 cm 
(2.6 in.) 
7.0 cm 
(2.8 in.) 
6.0 cm 
(2.4 in.) 
LED Control Input 
Dry Contact, N.O. 
Maximum Cable 
Distance to 
Controller 
18-AWG: 150 m (500 ft) 
20-AWG: 90 m (300 ft) 
Frequency 
13.56 MHz 
Bit Rate 
106 KHz 
* Measured using a Rosslare MIFARE Classic EV1 card or equivalent. Range also 
depends on installation environment, reader voltage, and proximity to metal.
 
2.2
 
Environmental Characteristics 
Specifications  AY-M5B 
AY-H5B 
AY-L5B 
AY-K5B 
Operating Temp. 
Range 
-31°C to 63°C (-25°F to 145°F) 
Operating 
Humidity Range 
0 to 95% (non-condensing) 
2.3
 
Physical Characteristics 
Model  
Dimensions  
(H x W x D) 
Weight  
AY-M5B 
89 x 89 x 15 mm 
(3.5 x 3.5 x 0.6 in.) 
120.3 g 
(4.2 oz.) 
AY-H5B 
110 x 75 x 15 mm 
(4.3 x 3.0 x 0.6 in.) 
119.9 g 
(4.2 oz) 
AY-L5B 
145 x 43 x 20 mm 
(5.7 x 1.7 x 0.8 in.) 
115.2 g 
(4.1 oz) 
AY-K5B 
80 x 40 x 12.8 mm 
(3.2 x 1.6 x 0.5 in.) 
75.5 g 
(2.7 oz) 
3.
  Installation 
 
Installation of an RFID reader adjacent to metallic surfaces 
might alter the reader’s specifications. To diminish this 
interference, use a plastic spacer when mounting the reader. 
3.1
 
Installation Kit 
The installation kit consists of the following items to be used during 
the installation procedure: 
 
Two pan head mounting screws and screw anchors 
3.2
 
Mounting 
Before mounting, you should determine the best location for the 
reader. 
To mount the reader: 
1.
  Drill two holes for mounting the reader on the wall. 
2.
  Insert a screw anchor into each hole. 
3.
  Drill a 10-mm (7/16”) hole for the cable. If mounting on metal, 
place a grommet or electrical tape around the edge of the hole. 
4.
  Remove the screw from the bottom of the unit. 
5.
  Remove the reader's snap-off front cover. 
6.
  Insert the unit’s cable wire into the cable hole and wire the unit as 
described in Sectio
 3.3. A linear type power supply is 
recommended. 
7.
  Align the two holes of the reader with those drilled in the wall and 
firmly attach the reader to the wall with two screws (Figure 2). 
Figure 2: Inserting Mounting Screws (similar for all models) 
 
8.
  Relocate the front cover onto the reader. 
9.
  Secure the front cover with the screw at the bottom of the unit.