READING ALARM MEMORY AND TROUBLE DATA
 
16 
D-300886 
SYSTEM TROUBLES 
• 
AC Supply Failure - There is no power and the 
system is working on backup battery power (this 
trouble is reported 5 minutes after its occurrence). 
• 
System Jammed - A radio-frequency signal is 
blocking communication channel of sensors and 
control panel.  
• 
Communication failure - A message could not 
be sent to the central monitoring station or to a 
private telephone (or a message was sent but 
was not acknowledged). 
• 
CPU low battery - The backup battery within 
the control panel is weak and must be replaced 
(see Chapter 9 - Replacing Backup Battery). 
• 
CPU tamper - The control panel is being 
tampered with. 
• 
Fuse Trouble - The siren fuse is burnt out. 
IMPORTANT! If the trouble beeps bother you, 
disarm the system again (even though it is already 
disarmed). This will cancel the trouble beeps for 4 
hours. 
B. Investigating Trouble Sources
 
In a state of trouble, a flashing TRBL message is 
displayed as shown in the following examples: 
READY             HH:MM 
     (alternating)        
READY             TRBL 
or, if the system is not ready for arming -
 
NOT READY          HH:MM 
     (alternating)        
NOT READY       TRBL 
You can review the current troubles one by one, by 
clicking the 
 button. 
EXAMPLE: The kitchen sensor - zone No. 9 - has 
been inactive and the living room sensor - zone No. 
15 - has reported a low battery. However, these 
troubles do not prevent the system from being “ready 
to arm”. 
To investigate the source of trouble, proceed as 
follows: 
PRESS RESULTANT 
DISPLAY 
READY      HH:MM 
 
Z09 INACTIVE 
 
 
     (alternating)      
 
 
KITCHEN 
Z15 LOW BATTERY 
 
 
     (alternating)      
 
 
LIVING ROOM 
 
In response to further clicking of 
, the 
display will show details of other troubles (if any), or 
will revert to the initial alternating displays (see 
example above). 
Reviewing Memory & Troubles at 
Reviewing Memory & Troubles at 
Reviewing Memory & Troubles at 
Reviewing Memory & Troubles at 
the Same Time
the Same Time
the Same Time
the Same Time    
If alarms / tamper events are retained in the alarm 
memory and at the same time a state of trouble 
exists, the display will behave as shown below: 
READY             HH:MM 
     (alternating)        
READY             MEMORY 
     (alternating)        
READY             TROUBLE 
or, if the system is not ready for arming - 
NOT READY     HH:MM 
     (alternating)        
NOT READY     MEMORY 
     (alternating)        
NOT READY       TRBL 
Note (not applicable to PowerMaxComplete that does 
not have VOICE feature): When a voice message is in 
memory, the MSG display will also appear (as shown 
in 
Chapter 3 - Recording a Message). 
To read status information - memory data, open zones 
and trouble sources (in this order) - click the 
 button repeatedly. The memory content 
will be displayed first, in the same manner shown in 
Chapter 5 - Reviewing Alarm / Tamper Memory. If the 
system is not ready, open zone information will follow 
in the same manner as shown in Chapter 2 - 
Preparing to Arm. Trouble sources will be displayed 
last, in the same manner shown in Chapter 5 - 
Reviewing Trouble Information. 
Correcting Trouble Situations
Correcting Trouble Situations
Correcting Trouble Situations
Correcting Trouble Situations    
The trouble indications (illuminated TROUBLE 
indicator and flashing TRBL message) are cleared 
once you eliminate the cause for trouble. If you do 
not know how to cope with a trouble situation, 
report it to your installer and seek his advice. 
INACTIVITY:
 
Once an inactive sensor or wireless 
commander renews its periodical transmissions, the 
inactivity trouble no longer exists and will no longer 
be indicated by the control panel. 
LOW BATTERY: Upon replacing the battery in a 
wireless device in a keyfob or in a wireless 
commander that reported a low battery, the next 
transmission made by the relevant sensor will include 
a “battery restored” message, and “low battery” will no 
longer be indicated by the control panel. 
SYSTEM TROUBLE: Correction of any one of the 
system troubles is automatically sensed by the control 
panel, and the trouble indication is cleared accordingly.