Product Engineering Specification 
 
Document 
PES-K33440 Rev
0.8
March 27, 2008
 
 
 
 
 
 Confidential 
Page 10 of 19
 
 
 
•  The CLA power supply for the USB shall meet the following technical requirements: 
a. Input 
Surge 
1.  While the circuit is operating at MAX load and Min load the line 
voltage is switched to the surge voltage 
a.  12Vdc to 40Vdc for 16msec, back to 12Vdc.  Repeated 5 
times at 50% duty cycle 
2.  There shall be no component damage, Voltage / logic signals 
shall remain within specified limits, No loss of performance and 
no permanent damage. 
b.  Identity line Signals (USB) 
1.  With no load on the circuit measure the voltages on D+ and D- 
2.  The voltage must fall within the below limits 
a.  D+ : 1.91V to 2.12V 
b.  D-:  1.91V to 2.12V 
c.  Load / Line / Regulation 
1.  While the load on one output is increased in steps to a 
predetermined table, the output voltage deviations are noted.  
Test is repeated for different input voltages 
2.  Output Voltage range 
a. Vmin=4.85v 
b. Vnom=5.0v 
c. Vmax=5.25v 
Regulation (V) 
Input Voltage 
(Vdc) 
0.0A  0.25A 0.50A 0.70A  1.0A 
10V 
   
Na 
Na 
12V 
   
Na 
Na 
14V 
   
Na 
Na 
 
 
 
d.  Dynamic Line Response 
1.  The PSU is subject to a +2Vdc line variation.  The output loads 
are chosen to give the worst case condition.  No load capacitors 
shall be used. 
2.  The PSU should not undershoot or overshoot beyond the 
regulation limits (4.85Vmin, 5.25 Vmax) 
e. Turn 
off/on 
Characteristics 
1.  All timing are to measured with a 5uF capacitive loading and 12V 
DC input voltage. 
a. Turn-on 
delay 
after DC input applied:  T1<4.0 sec at 
which point the output voltage must have stabilized 
between 4.85 and 5.25 V DC. 
b.  Output rise time (10% to 90% regulation):  T2 <20ms 
2. All 
parameters 
must 
be within specification 
a.  The output voltage overshoot upon the application or 
removal of the input voltage shall be less than 10% 
above the nominal voltage. 
b.  There must be a smooth and continuous ramp of the DC 
output voltage from 10% to 90% of its final set point 
within the regulation band, while loaded as specified in