Adtran T1 ESF CSU ACE 1204025L1 Manual Do Utilizador

Códigos do produto
1204025L1
Página de 66
Chapter 1. Introduction
T1 ESF CSU ACE User Manual
26
© 2004 ADTRAN, Inc
61204025L1-1B
Pattern Generation
The T1 ESF CSU ACE offers three test patterns: All Ones, All Zeros, and 1:8. These patterns can be 
initiated from the front panel, through the EIA-232 control port, or remotely via a management software 
like T-Watch.
All Ones
The All Ones pattern sends ones in all the payload bits.
All Zeroes
The All Zeros pattern sends zeros in all the payload bits and is useful for testing line code configuration 
(AMI/B8ZS mismatches).
1 in 8 (1:8)
Each channel of the T1 has only one bit set. This pattern is used in conjunction with external test 
equipment to determine whether the T1 line is performing acceptably under a stress condition.
APPLICATIONS
Three applications are shown in this section. Figure 1-7 on page 27 shows a general data application; 
Figure 1-8 on page 28 shows a general voice application; and Figure 1-9 on page 28 shows a channel bank 
application.