Climax Technology Co Ltd HPGWG5DT16 Manual Do Utilizador

Página de 93
 
17
 
Bypass 
This function ONLY applies to Remote Control or Door Contact with Set/Unset attribute 
enabled.
 
 
Latch Report ON: When the device is used to change systm arm mode, the 
Control Panel will report the arm/disarm action by the particular device. 
 
Latch Report OFF: When the device is used to change systm arm mode, the 
Control Panel will not report the arm/disarm action by the particular device. 
 
Set/Unset 
This function is for Door Contact only. This function allows Door Contact to control 
system mode.
 
 
Normal Close: The system will be armed when the Door Contact is opened, and 
disarmed when Door Contact is closed. 
 
Normal Open: The system will be armed when the Door Contact is closed, and 
disarmed when Door Contact is open. 
 
24HR 
This function enables the device to activated selected alarm event whenever it is 
triggered regardless of system mode. System mode response will be disabled if 24HR 
attribute is enabled.
 
System Mode Attributes: 
The System Mode Attributes determines system behavior under particular arming mode 
when the sensor is triggered. 
 
No Response 
 
When a sensor with No Response is triggered, the Control Panel will not 
respond.  
 
Start Entry Delay 1Start Entry Delay 2 
 
When the system is under Full Arm or Home Arm mode, if a sensor with Start 
Entry Delay 1/2
 attribute is triggered, Control Panel will start an entry countdown 
period to give enough time to disarm the system.   
 
When the Control Panel is in the Disarm mode, if a sensor with Start Entry Delay 
1/2
 attribute is triggered, the Control Panel will immediately report a burglar 
interior alarm (CID code: 132).    
 
When the Control Panel is in the Full Arm mode, if a sensor with Start Entry 
Delay 1/2
 attribute is triggered, the Entry Delay 1/2 timer starts counting down.   
If no correct pin code is entered during the entry delay timer to disarm the system, 
the Control Panel will report a burglar perimeter alarm (CID code:131
immediately after entry delay timer 1/2 expires.     
 
When the Control Panel is in the Home Arm 1/2/3 mode, if a sensor with Start 
Entry Delay 1/2
 attribute is triggered, the Entry Delay 1/2 timer starts counting 
down.    If no correct pin code is entered during the entry delay period to disam 
the system, the Control Panel will report a burglar interior alarm (CID code: 132
immediately after entry delay timer 1/2 expires.     
 
Chime 
 
When the system is in Arm/ Home Arm 1/ Home Arm 2/ Home Arm 3 mode, if a 
sensor set to Chime is triggered, the Control Panel will sound a Door Chime 
(Ding-Dong Sound).