If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns 
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before 
the Entry Delay Timer expires, the alarm will be activated and the panel will send report. 
 
Entry Delay 2 for Full Arm: Set Entry Delay Timer 2 for full arm mode. When a sensor 
set to Start Entry Delay 2 is triggered under Full Arm mode, the control panel will begin 
Entry Delay Timer countdown according to duration set with this option 
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns 
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before 
the Entry Delay Timer expires, the alarm will be activated and the panel will send report. 
 
Exit Delay for Full Arm: Set the Exit Delay Timer when entering Full Arm mode. When 
the user changes system mode to Full Arm, the panel will begin Exit Delay Timer 
Countdown and enter Full Arm mode when the timer expires. The user must leave area 
protected by sensors before the timer expires, otherwise an alarm will be activated with 
the sensor is triggered. 
 
Entry Delay 1 for Home Arm: Set Entry Delay Timer 1 for Home Arm mode. When a 
sensor set to Start Entry Delay 1 is triggered under Home Arm mode, the control panel 
will begin Entry Delay Timer countdown according to duration set with this option 
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns 
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before 
the Entry Delay Timer expires, the alarm will be activated and the panel will send report. 
 
Entry Delay 2 for Home Arm: Set Entry Delay Timer 2 for Home Arm mode. When a 
sensor set to Start Entry Delay 2 is triggered under Home Arm mode, the control panel 
will begin Entry Delay Timer countdown according to duration set with this option 
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns 
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before 
the Entry Delay Timer expires, the alarm will be activated and the panel will send report. 
 
Alarm Length: Set the duration the external siren should sound when an alarm is 
activated.  
Sound Setting 
 
Door Chime Setting: this function is available only when the attribute of Door Contact 
(DC) and/or PIR detector (IR) is set as Door Chime
The Control Panel sounds a Door Chime (Ding-Dong Sound) while the DC and/or IR is 
activated in Disarm / Full / Home / Entry mode. 
 
Entry Delay Sound for Full Arm: this is for you to decide whether the Control Panel 
sounds count-down beeps and volume of beep during the entry delay time in the full 
arm mode.   
 
Exit Delay Sound for Full Arm: this is for you to decide whether the Control Panel 
sounds count-down beeps and volume of beep during the exit delay timer in the full arm 
mode.  
 
Entry Delay Sound for Home Arm: this is for you to decide whether the Control Panel 
sounds count-down beeps and volume of beep during the entry delay time in the home 
arm mode.   
 
Exit Delay Sound for Home Arm: this is for you to decide whether the Control Panel 
sounds count-down beeps and volume of beep during the exit delay timer in the
 
home 
arm mode. 
 
Warning beep: this is for you to decide whether the Control Panel will sound a warning 
beep whenever a fault condition has been detected and displayed. The warning beep 
will be silenced after the Fault message has been read by the user. When a new fault 
condition is detected, it will then again emit a warning beep every 30 sec.