Climax Technology Co Ltd WSF1 Manual Do Utilizador

Página de 3
LEARNING IN WATER SENSOR: 
Step 1. Open the cover by removing the bottom fixing screw on the Water Sensor. 
Step 2. Insert the battery in the battery compartment 
Step 3. Program the Control Panel to enter the learn mode. 
Step 4. Press the Learn/Test button once to transmit learn code, the Water Sensor will emit 1 beep and the 
Red LED will flash once 
Step 5. If the Control Panel receives the learn code, it will display the information accordingly, refer to the 
Control Panel manual to complete the learning process.
 
 
Step 6. Replace the cover on the Water Sensor 
Step 7. The Learning-In process is now complete. 
 
MOUNTING WATER SENSOR: 
The Water Sensor can be deployed on the ground or mounted on the wall 
Ground Deployment 
When deployed on the ground, the Water Sensor detects water through the probes protruding from its 
back cover. 
1. (If extension probe is connected) Open the cover by removing the bottom fixing screw on the Water 
Sensor. 
2. Remove the extension probe from the terminal. 
3. Replace the cover. 
4. Put the Water Sensor on the ground with the back cover facing downward. 
Wall Mounting: 
For wall mounting, the Water Sensor must be connected to the external extension probe, then installed at 
desired height. 
1.  Remove the fixing screw and cover assembly. 
2.  Use a Philip screw driver to turn counter-clockwise and loosen the 2 screws on the extension probe 
terminal. (Figure 1
3.  Insert the extension probe into the terminal, use the Philip screw driver to turn clockwise and tighten 
and screws to secure the probe. (Figure 2
Figure 1
                                                                         
Figure 2
 
 
 
 
4.  Break through the wall mounting knockouts on the base. 
5.  Using the holes as a template, drill holes in the surface. 
6.  Insert the wall plugs if fixing it into plaster or brick. 
7.  Screw the base into the wall plugs. 
8.  Screw the cover back onto its base. 
9.  Find the plastic clip included in the package, insert the 
extension probe in the clip. (Figure 3
10. Remove the cover double-side adhesive tape on the clip and 
apply the clip to desired location on the wall to secure the 
probe. 
 
 
 
Figure 3