Installation
TB9400 Installation and Operation Manual
© Tait Electronics Limited September 2011
5.1.3
Equipment Ventilation
Always ensure there is adequate ventilation around the 
base station
Warning!!
Do not operate it in a sealed cabinet. You must 
keep the ambient temperature within the speci-
fied range, and we strongly recommended that 
you ensure that the cooling airflow is not 
restricted.
Important
The cooling fans are mounted on the front panel and will 
only operate when the panel is fitted correctly to the front 
of the subrack. To ensure adequate airflow through the 
base 
station
, do not operate it for more than a few minutes with 
the front panel removed (e.g. for servicing purposes).
5.1.4
Ambient Temperature Sensor
The ambient temperature reading for the 
base station
 is provided by the 
temperature sensor located on the front panel circuit board.