Tait International Limited TBCK4B Manual Do Utilizador

Página de 132
DRAFT 4 
86
Installation
TB9400 Installation and Operation Manual
© Tait Electronics Limited September 2011
5.6.7
Connecting a 1 PPS Source
A 1 PPS signal is required for simulcast 
base stations
This and the external 
frequency reference can be provided, for example, by a Tait T801-4 
Frequency Reference. For more information, see the T801-4 Installation 
and Operation Manual (MBA-00033-xx).
Use a 50 
Ω coaxial cable (RG58 or RG223) to connect the source to the 
base station’s
 1 PPS input. You can daisy-chain up to six 
base stations
 using 
T-junctions. We recommend that the cable length between the first and last 
load is kept to a minimum. This will reduce any propagation variation 
between 
base stations
. The maximum overall cable length is 30 m. Terminate 
the last connection with a 50 
Ω resistor, otherwise reflections of the 1 PPS 
pulse may occur. 
5.6.8
Ethernet Connection
The RJ-45 socket on the reciter’s rear panel provides the 10BASE-T or 
100BASE-T Ethernet connection to the other devices in the network. Use 
Cat-5 cable to connect this socket to the TaitNet P25 Network via a router 
or switch. 
If necessary, refer to 
connection pin allocations.
Figure 5.11
Daisy-chaining a 1 PPS input
The longest length of cable must be between 
the source and the first 
base station
use short lengths of cable 
between each 
base station
maximum of six 
base station
 
loads on one 1 PPS output
50 
Ω termination