Data Field Descriptions
DELAY PROGRAMMING (
✻
34–
✻
36)
NOTE: The control validates the data entered in these fields. If the selection is not valid the control will emit a single long beep indicating that
the selection has been rejected. The control replaces the selection with the default value which is displayed on the keypad.
✻
34
Exit Delay
Entries from 45-97
Entered Value
Delay in Seconds
45-96 45-96
97 120
The system will wait the time entered before sounding an alarm if the exit
door is left open after the system has been armed.
UL installations: must be set for a maximum of 60 seconds
SIA Guidelines: must be set to a minimum of 45 seconds
door is left open after the system has been armed.
UL installations: must be set for a maximum of 60 seconds
SIA Guidelines: must be set to a minimum of 45 seconds
Note: Entries less than 45 seconds will result in a 45 second exit delay.
✻
35
Entry Delay 01
30-99 = entry delay time in seconds.
Entered Value
Delay in Seconds
30-96 30-96
97 120
98 180
99 240
The system will wait the time entered before sounding alarm upon entering
if system is not disarmed.
UL installations: must be set for a maximum of 45 seconds.
SIA Guidelines: must be set to a minimum of 30 seconds
if system is not disarmed.
UL installations: must be set for a maximum of 45 seconds.
SIA Guidelines: must be set to a minimum of 30 seconds
Note: Entries less than 30 seconds will result in a 30 second exit delay.
UL/SIA The sum of entry delay 1 entered in Field ✻35 and the burglary
abort window entered in ✻50 should not exceed 1 minute.
✻
36
Entry Delay 02
30-99 = entry delay time in seconds.
Entered Value
Delay in Seconds
30-96 30-96
97 120
98 180
99 240
The system will wait the time entered before sounding alarm upon
entering.
UL installations: must be set for a maximum of 45 seconds
SIA Guidelines: must be set to a minimum of 30 seconds
entering.
UL installations: must be set for a maximum of 45 seconds
SIA Guidelines: must be set to a minimum of 30 seconds
Note: Entries less than 30 seconds will result in a 30 second exit delay.
UL The sum of entry delay 2 entered in Field ✻36 and the burglary
abort window entered in ✻50 should not exceed 1 minute.
✻
38
Confirmation of Arming Ding
0 = no arming confirmation ding after arming system
by LYNXR keypad or RF keypad
1 = arming confirmation ding after arming system by
LYNXR keypad or RF keypad
2 = arming confirmation ding after arming from RF
keypad only
Confirmation of arming is provided by a 1/2 second external sounder “ding” .
The confirmation ding only sounds when LYNX is Armed Away or disarmed
after being Armed Away.
If Option 1 is selected, confirmation of arming is provided by a 1/2 second
sounder “ding” that sounds when closing report is sent, or at the end of exit
delay.
If Option 2 is selected the external sounder “ding” occurs immediately after
arming from an RF keypad.
Note: If LYNX is armed by RF button (key fob), a confirmation ding occurs
The confirmation ding only sounds when LYNX is Armed Away or disarmed
after being Armed Away.
If Option 1 is selected, confirmation of arming is provided by a 1/2 second
sounder “ding” that sounds when closing report is sent, or at the end of exit
delay.
If Option 2 is selected the external sounder “ding” occurs immediately after
arming from an RF keypad.
Note: If LYNX is armed by RF button (key fob), a confirmation ding occurs
immediately after arming regardless of field *38 settings. If LYNX is
disarmed by RF button (key fob), additional disarming confirmation
ding is provided. The ding occurs immediately after disarming and is
longer than arming confirmation ding.
disarmed by RF button (key fob), additional disarming confirmation
ding is provided. The ding occurs immediately after disarming and is
longer than arming confirmation ding.
✻
39
Cross Zone Timer
Value Time
Window
0 = No Cross Zoning
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
4 = 60 seconds
5 = 1 minute, 15 seconds
6 = 1 minute, 30 seconds
7 = 1 minute, 45 seconds
8 = 2 minutes
9 = 2 minute, 15 seconds
# + 10 = 2 minute, 30 seconds
# + 11 = 2 minute, 45 seconds
# + 12 = 3 minutes
# + 13 = 3 minute, 15 seconds
# + 14 = 3 minute, 30 seconds
# + 15 = 3 minute, 45 seconds
Sets the maximum amount of time in which two cross zones must be
tripped in an armed system to send an alarm message to the Central
Station. If only one cross zone is tripped during this time, a trouble
message (CID code 380) for that zone is sent to the Central Station.
Program Zone list 2 (using *81 Zone List Menu Mode) with the two
zones that are to be cross zoned.
Notes: (1) If option
tripped in an armed system to send an alarm message to the Central
Station. If only one cross zone is tripped during this time, a trouble
message (CID code 380) for that zone is sent to the Central Station.
Program Zone list 2 (using *81 Zone List Menu Mode) with the two
zones that are to be cross zoned.
Notes: (1) If option
✻
39 is set to “0” (no cross zoning) then Zone List 2
can be used for other purposes.
(2) Cross zoning will be disabled during entry and exit delays, if
there is already an alarm in the system, if one or both of the 2
cross zones is bypassed.
cross zones is bypassed.
If one of the 2 cross zones faults and remains faulted after the
cross zone time interval, the second cross zone can go into
alarm immediately, even after the cross zone time. This is to
detect scenarios involving multiple break-ins of a premises.
cross zone time interval, the second cross zone can go into
alarm immediately, even after the cross zone time. This is to
detect scenarios involving multiple break-ins of a premises.
UL This option is not for use in UL installations.