Data Field Descriptions 
 
DELAY PROGRAMMING (
34–
36) 
NOTE: The control validates the data entered in these fields. If the selection is not valid the control will emit a single long beep indicating that 
the selection has been rejected. The control replaces the selection with the default value which is displayed on the keypad. 
  
34
 
Exit Delay 
Entries from 45-97 
 
Entered Value 
Delay in Seconds 
45-96 45-96 
97 120 
 
 
 
The system will wait the time entered before sounding an alarm if the exit 
door is left open after the system has been armed. 
UL installations: must be set for a maximum of 60 seconds 
SIA Guidelines: must be set to a minimum of 45 seconds 
 
 
Note: Entries less than 45 seconds will result in a 45 second exit delay. 
 
35
 
Entry Delay 01 
30-99 = entry delay time in seconds. 
 
Entered Value 
Delay in Seconds 
30-96 30-96 
97 120 
98 180 
99 240 
 
 
 
The system will wait the time entered before sounding alarm upon entering 
if system is not disarmed.  
UL installations: must be set for a maximum of 45 seconds. 
SIA Guidelines: must be set to a minimum of 30 seconds 
 
 
Note: Entries less than 30 seconds will result in a 30 second exit delay. 
 
 
UL/SIA The sum of entry delay 1 entered in Field ✻35 and the burglary 
abort window entered in ✻50 should not exceed 1 minute. 
36
 
Entry Delay 02 
30-99 = entry delay time in seconds. 
 
Entered Value 
Delay in Seconds 
30-96 30-96 
97 120 
98 180 
99 240 
 
 
 
The system will wait the time entered before sounding alarm upon 
entering.  
UL installations: must be set for a maximum of 45 seconds 
SIA Guidelines: must be set to a minimum of 30 seconds
 
 
 
Note: Entries less than 30 seconds will result in a 30 second exit delay. 
 
 
UL  The sum of entry delay 2 entered in Field ✻36 and the burglary 
abort window entered in ✻50 should not exceed 1 minute.
 
38
 
Confirmation of Arming Ding 
0 = no arming confirmation ding after arming system 
by LYNXR keypad or RF keypad 
1 = arming confirmation ding after arming system by 
LYNXR keypad or RF keypad 
2 = arming confirmation ding after arming from RF 
keypad only 
 
Confirmation of arming is provided by a 1/2 second external sounder “ding” .
The confirmation ding only sounds when LYNX is Armed Away or disarmed 
after being Armed Away. 
 
If Option 1 is selected, confirmation of arming is provided by a 1/2 second 
sounder “ding” that sounds when closing report is sent, or at the end of exit 
delay. 
 
If Option 2 is selected the external sounder “ding” occurs immediately after 
arming from an RF keypad.   
 
Note: If LYNX is armed by RF button (key fob), a confirmation ding occurs 
immediately after arming regardless of field *38 settings. If LYNX is 
disarmed by RF button (key fob), additional disarming confirmation 
ding is provided. The ding occurs immediately after disarming and is 
longer than arming confirmation ding. 
 
39
 
Cross Zone Timer 
 
Value Time 
Window 
0 =  No Cross Zoning 
1 =  15 seconds 
2 =  30 seconds 
3 =  45 seconds 
4 =  60 seconds 
5 =  1 minute, 15 seconds 
6 =  1 minute, 30 seconds 
7 =  1 minute, 45 seconds 
8 =  2 minutes 
9 =  2 minute, 15 seconds 
# + 10 =  2 minute, 30 seconds 
# + 11 =  2 minute, 45 seconds 
# + 12 =  3 minutes 
# + 13 =  3 minute, 15 seconds 
# + 14 =  3 minute, 30 seconds 
# + 15 =  3 minute, 45 seconds 
 
Sets the maximum amount of time in which two cross zones must be 
tripped in an armed system to send an alarm message to the Central 
Station. If only one cross zone is tripped during this time, a trouble 
message  (CID  code  380)  for  that  zone  is  sent  to  the  Central  Station. 
Program Zone list 2 (using *81 Zone List Menu Mode) with the two  
zones that are to be cross zoned.  
 
Notes:  (1)  If option 
39 is set to “0” (no cross zoning) then Zone List 2 
can be used for other purposes. 
 
(2)  Cross zoning will be disabled during entry and exit delays, if 
there is already an alarm in the system, if one or both of the 2 
cross zones is bypassed.   
  
If one of the 2 cross zones faults and remains faulted after the 
cross zone time interval, the second cross zone can go into 
alarm immediately, even after the cross zone time. This is to 
detect scenarios involving multiple break-ins of a premises. 
 
UL This option is not for use in UL installations.