Honeywell International Inc. 8DLLYNXREN-5 Manual Do Utilizador

Página de 72
 
 
–50– 
System Operation 
 
U
U
U
ULLLL    
Alarm audio verification cannot be used for UL installations. 
 
Alarm Audio Verification (Two-Way Voice Feature) 
This feature allows the central station operator to listen, talk to or conduct a two-way conversation with an 
individual(s) at the premises. It also assists the operator in gathering information about the nature and 
location of the alarm that may be helpful in responding to police and fire departments. All LYNXR-ENSIA 
control panels are capable of supporting the Two-Way Voice feature. The LYNXR-ENSIA does not make 
system announcements when the Two-Way voice feature is active. 
Activation 
The LYNXR-ENSIA sends the “alarm message” followed by a “Listen-in-to-Follow message” (Contact ID® 
code 606) to the Central Station. The Listen-in-to-Follow message causes the Central Station’s digital 
receiver to temporarily hold the phone line for approximately 1-minute.  When the LYNXR-ENSIA receives 
the “kissoff” from the central station, indicating that the alarm message has been received, the Two-Way 
Voice (AVM) feature is activated in the (default) “Listen Mode” and sirens and keypad sounds are 
discontinued. The LYNXR-ENSIA transmits a beep acknowledgment to the Central Station, once per second. 
The beep alternates between two tones and indicates that the LYNXR-ENSIA is waiting for a session 
command from the Central Station operator.  Once a command is issued the beep acknowledgement is 
discontinued, however, if a command is not issued within two minutes the system will “time out” and the call 
will be terminated. 
Operator Commands  
The Central Station operator begins the session, which last 5 minutes, by entering one of the valid AVM 
commands shown in the table below. The session may be extended 5 minutes, without changing the 
operating mode, by pressing the [7] key on the touch-tone phone.  Selecting another operating mode also 
resets the session an additional 5 minutes.  During the last minute of the 5 minute, session, the LYNXR-
ENSIA generates two beeps every 30 seconds to alert the Central Station operator that the session is about 
to time out. The Central Station operator may then extend the session by pressing the [7] key on the touch-
tone phone.  If the session is not extended the phone line is disconnected, and the session is ended. Sessions 
may be ended at any time by pressing the [9] key on the touch-tone phone.  The AVM modes are described as 
follows:   
Note:   When entering AVM commands make sure the Central Station receiver has been disconnected from the phone line, otherwise AVM 
commands may not go through. 
  Key 
Function 
Talk Mode:  Pressing the [1] key on the touch tone phone, enables one-way voice communication from the central station 
to the violated premises, and allows the operator to talk communicate through the LYNXR-ENSIA speaker. In this mode 
the ARMED (red) and READY (green) LEDs blink alternately. 
VOX (Voice) Mode:  Pressing the [2] key on the touch-tone phone, enables two-way voice communications between the central 
station and the violated premises.  In this mode the ARMED (red) and READY (green) LEDs blink alternately. 
Listen Mode: Pressing the [3] key on the touch-tone phone, enables one-way audio from the violated premises to the central 
station.  The Listen Mode is the start up default mode of the voice feature and allows the operator to listen through the 
LYNXR-ENSIA microphone. This mode does not affect the existing LED pattern. 
Extends the session 5 minutes without changing its operating mode. 
Ends the session and disconnects the phone line.